CT image generation from ultrashort echo time MRI for dosimetric assessment in lung cancer radiotherapy.
Kaiyi Zheng, Xudong Xue, Qi Zhang, Fengqin Zhou, Jia Xu, Xingyu Wang, Xiaopeng Song, Wei Mao,
Department of Radiology, Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. · Department of Radiation Oncology, Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Key points
From the paper's conclusion- FFTSC-Net demonstrates high image fidelity and dosimetric accuracy, supporting its potential for MRI-only radiotherapy planning in patients with lung cancer.
Abstract
BACKGROUND AND PURPOSE: To facilitate magnetic resonance imaging (MRI)-only radiotherapy workflows and overcome the lack of electron density information in MRI for accurate radiotherapy dose calculation, we proposed a cycle-consistent generative adversarial network-based framework, Fast Fourier Transform Spatial-Channel Net (FFTSC-Net). This study aimed to synthesize high-quality synthetic computed tomography (sCT) from lung ultrashort echo time-MRI (UTE-MRI) and assess its potential clinical dosimetric viability. MATERIALS AND METHODS: UTE-MRI and CT data from 60 patients with lung cancer were retrospectively collected and spatially aligned through deformable registration. FFTSC-Net was developed by integrating spatial and channel reconstruction convolution, squeeze-and-excitation, and residual fast Fourier transform modules, alongside a dual contrastive loss function. The synthesis quality was evaluated using structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and mean absolute error (MAE). The clinical feasibility was assessed through Hounsfield unit (HU) consistency analysis in organs at risk (OARs) and planning target volume (PTV), dose volume histogram parameters, and gamma passing rates. RESULTS: FFTSC-Net achieved an SSIM of 0.80, PSNR of 20.07 dB, and MAE (HU) of 59.31. No statistically significant differences were observed in HU distributions for lungs, spinal cord, and PTV compared with planning CT (p > 0.05). Dosimetric analysis revealed no significant differences across all PTV and OAR indices (p > 0.05). Gamma passing rates reached 95.39% (2%/2 mm) and 98.08% (3%/3 mm). CONCLUSION: FFTSC-Net demonstrates high image fidelity and dosimetric accuracy, supporting its potential for MRI-only radiotherapy planning in patients with lung cancer.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical implementation of deep learning-based synthetic CT for MRI-only volumetric modulated arc therapy in head and neck and pelvic cancer patientsRadiation Oncology · 2025
- Evaluation of U-Net Based Architectures for Synthetic CT Generation from Dual-Contrast MRI.Biomedical physics & engineering express · 2026
- MRI-Driven Dual-Energy CT Synthesis via Conditional Denoising Diffusion Probabilistic Models for MRI-only Radiotherapy and ProtontherapyarXiv · 2026
- Deep learning-based super-resolution ultrashort echo time MRI combined with free-breathing Star-VIBE dynamic contrast-enhanced MRI for characterization of Lung-RADS 4 pulmonary nodules.Quantitative imaging in medicine and surgery · 2026
- MRI-only workflow for preclinical ion beam therapy: Deep-learning-based synthetic CT generation from ultra-high-field small animal MRI.Zeitschrift fur medizinische Physik · 2026
- Generative structure-guided denoising diffusion probabilistic model for MR to CT image synthesis in radiotherapy planning.Physics in medicine and biology · 2026