Dose accuracy evaluation of multi-leaf collimator modeling in single-isocenter multi-target stereotactic radiosurgery.
Farnaz Rahim Li, Rex A Cardan, Joel A Pogue, Natalie N Viscariello, Rodney J Sullivan, John B Fiveash, Carlos E Cardenas, Richard A Popple
Department of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, AL, USA.
Key points
From the paper's conclusion- DLG showed slightly better VMAT SRS agreement than ELM, but differences were clinically negligible. ELM's model-based MLC configuration removes user-specific DLG variability, potentially improving dose-calculation precision and consistency across institutions.
Abstract
BACKGROUND AND PURPOSE: Accurate modeling of multi-leaf collimators is critical for dose calculation in stereotactic radiosurgery (SRS), where steep dose gradients and small target volumes amplify modeling uncertainties. This study compared enhanced leaf modeling and dosimetric leaf gap approaches using two clinically implemented dose calculation algorithms in single-isocenter SRS plans. MATERIALS AND METHODS: Sixty clinical volumetric modulated arc therapy (VMAT) single-isocenter SRS plans (30 single-target, SIST; 30 multi-target, SIMT) were selected and measured with a two-dimensional diode array, normalized to a point measurement. Dose was calculated using both enhanced leaf model (ELM) and dosimetric leaf gap (DLG) models and the anisotropic analytical algorithm (AAA) and Acuros XB (AXB) algorithms across several spot-size configurations. Plan quality assurance was assessed using gamma analysis for several dose-distance criteria. Dose differences were further analyzed as functions of target size and distance from isocenter. RESULTS: Under 2%/1 mm gamma criteria, AXB-DLG having spot size 0.5 × 0.5 mm2 showed the highest median and mean gamma pass rate (fraction of points having gamma >1), 98.7% and 97.4% respectively, while AXB-ELM having spot-size 0.5 × 0.7 mm2 had the lowest, 98% and 96.3%, respectively. SIST and SIMT plans showed no clinically significant differences. AAA-ELM (spot size: 0 × 0 mm2) achieved the highest median and mean gamma values, while AXB-DLG remained robust across plan types. Dose calculations were accurate for both configurations, with minimal mean differences (0.0%, range - 2.7% to +1.8%) reported. CONCLUSIONS: DLG showed slightly better VMAT SRS agreement than ELM, but differences were clinically negligible. ELM's model-based MLC configuration removes user-specific DLG variability, potentially improving dose-calculation precision and consistency across institutions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Robust enhanced leaf model implementation for beam-matched linear accelerators: Impact of physical leaf gap variations.Journal of applied clinical medical physics · 2026
- Evaluation of GPU-accelerated Monte Carlo beam and agility MLC modeling in the Monaco treatment planning system.Journal of applied clinical medical physics · 2026
- Clinical impact of enhanced leaf modelling on multi-metastatic intracranial SRT delivered on Halcyon: a modest but consistent dosimetric effect.Physical and engineering sciences in medicine · 2026
- How robust are secondary dose algorithms for Patient-Specific quality assurance in modulated stereotactic Radiosurgery?Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- ROC-based evaluation of tight gamma criteria for detecting MLC and jaw positioning errors in brain SRS using SRS MapCHECK.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026
- Dosimetric comparison of the Anisotropic Analytical Algorithm and Acuros XB for single-fraction cranial stereotactic radiosurgery with a 6 MV flattening filter-free beam.Biomedical physics & engineering express · 2026