Clinical implementation of intensity modulated proton therapy in breath-hold for mediastinal lymphoma patients using surface monitoring and nasal high-flow therapy.
Gloria Vilches-Freixas, Kim van der Klugt, Richard Canters, Esther Kneepkens, Fleur Vereijken, Maud Cobben, Maud van den Bosch, Indra Lubken,
Maastro, Maastricht Radiation Oncology Institute, Maastricht, the Netherlands.
Key points
From the paper's conclusion- IMPT-BH with OSS and NHFT is feasible for treating mediastinal lymphoma, providing stable BHs, and acceptable treatment times. Interfraction motion was slightly higher than intrafraction motion, suggesting that combining bone alignment with soft tissue adjustment could improve setup accuracy.
Abstract
BACKGROUND AND PURPOSE: We report our first clinical experience treating mediastinal lymphoma patients in breath-hold (BH) with intensity modulated proton therapy (IMPT), using optical surface scanning (OSS) for beam gating and nasal high-flow therapy (NHFT). Moreover, we evaluated BH stability throughout treatment and assessed adequacy of applied treatment margins. MATERIALS AND METHODS: Thirteen patients received IMPT-BH with anterior beams supported by NHFT and OSS. OSS enabled gated treatment delivery with a 3 mm breathing window and a maximum isocenter shift of 5 mm. OSS respiratory traces were synchronized with machine log-file beam delivery data to identify beam-on periods. BH stability, BH duration, and OSS-derived isocenter shifts were assessed during cone beam CT (CBCT) and treatment. Margin adequacy was evaluated using post-treatment CBCTs acquired for 34 fractions (2-3 CBCTs per patient), while plan robustness over time was assessed with weekly repeat-CTs. RESULTS: Analyzing 187 fractions, the median number of BHs was 1 [1-6] per CBCT and 5 [3-20] per treatment delivery. Intra- and inter-BH surface stability were within 1 mm, and the median isocenter deviation during beam delivery was less than 3 mm. Average fraction time was 44 ± 13 min, decreasing as patients became more experienced. One plan adaptation was required in the entire cohort. Residual target shifts during BH treatments were < 8 mm, comparable to motion in free-breathing. CONCLUSIONS: IMPT-BH with OSS and NHFT is feasible for treating mediastinal lymphoma, providing stable BHs, and acceptable treatment times. Interfraction motion was slightly higher than intrafraction motion, suggesting that combining bone alignment with soft tissue adjustment could improve setup accuracy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative evaluation of plan robustness in proton and photon radiotherapy in deep inspiration breath-hold for mediastinal lymphomas throughout the treatment course.Physics and imaging in radiation oncology · 2026
- Breathing-phase selection for gated proton therapy in lung cancer towards temporally targeted ultra-high dose rate delivery.Physics and imaging in radiation oncology · 2026
- Dosimetric Impact of Residual Intrafraction Motion in Gated MR-Guided Prostate SBRT With Focal Dose IntensificationmedRxiv · 2026
- EP09.29 Image-guided intraoperative radiotherapy for resectable brain metastases: Prospective evaluation of dosimetric accuracy and clinical outcomesNeuro-Oncology · 2026
- Learning to breathe for radiation therapy: A scoping review of deep inspiration breath-hold trainingCritical Reviews in Oncology/Hematology · 2026
- Dosimetric and radiobiological evaluation of a spatially fractionated core-boost strategy in lung metastases within 5 mm of the esophagus: Single-center plan-comparison study.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026