An Updated Prospective Quantitative Analysis of Symptoms and Safety for Human Low-Intensity Focused Ultrasound Neuromodulation.
Aditya Kapoor, Thomas Crahan, Wynn Legon
Fralin Biomedical Research Institute at Virginia Tech Carilion, Roanoke, VA, USA. · Virginia Tech Carilion School of Medicine, Roanoke, VA, USA.
Key points
From the paper's conclusion- Across a prospective, sham-controlled data set, LIFU added no measurable symptom burden and was well tolerated in healthy adults, with comparable tolerability in patients. These findings establish a benchmark for the safety of human LIFU neuromodulation and a foundation for its therapeutic translation.
Abstract
OBJECTIVES: Low-intensity focused ultrasound (LIFU) is a noninvasive neuromodulation technique with a favorable safety profile in healthy volunteers. Participant-experienced symptoms, however, remain inconsistently measured, and prospective benchmarks are lacking. Here, we prospectively characterized symptoms associated with LIFU neuromodulation across eight studies using a standardized Report of Symptoms (ROS). MATERIALS AND METHODS: We compiled 629 sessions (472 LIFU and 157 sham) in 106 healthy adults (28.1 ± 9.8 years) across eight cortical and subcortical targets (500 kHz; extracranial spatial-peak pulse-average intensity 3.9-33.3 W/cm2; mechanical index 0.5-1.4). The ROS rated 17 symptom domains from 0 (absent) to 3 (severe) before and after each session. New-onset incidence, symptom severity, and total symptom burden were compared between LIFU and sham. The same instrument was applied in 35 patients with chronic pain. Symptom profiles after LIFU were indistinguishable from sham across all 17 domains. RESULTS: The total symptom burden averaged approximately one domain per session and did not increase after LIFU (0.94-1.03; p = 0.120). The postintervention burden was predicted by the baseline burden (β = 0.344, p < 0.001) but not by the stimulation condition (p = 0.226). New-onset symptoms did not increase across up to 27 LIFU sessions (odds ratio = 0.99, p = 0.73) and were weakly and nonsignificantly related to acoustic intensity (ρ = 0.37). CONCLUSION: Across a prospective, sham-controlled data set, LIFU added no measurable symptom burden and was well tolerated in healthy adults, with comparable tolerability in patients. These findings establish a benchmark for the safety of human LIFU neuromodulation and a foundation for its therapeutic translation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A standardized framework for reporting participant-experienced events in low intensity focused ultrasound neuromodulationBrain stimulation · 2026
- Low-intensity focused ultrasound for neuromodulation: mechanisms, parameters, and emerging clinical applications-a critical review.Frontiers in neuroscience · 2026
- Low‐intensity focused ultrasound neuromodulation for drug‐resistant epilepsy: A randomized, sham‐controlled crossover trialEpilepsia · 2026
- Low-intensity focused ultrasound for neuromodulation: neuroimaging and neurointerventional perspectives.AJNR. American journal of neuroradiology · 2026
- Risk of low-frequency ultrasound stimulation: Response to “Brain injury during focused ultrasound neuromodulation for substance use disorder”Brain stimulation · 2026
- Precision meets plasticity: engineering and neurobiological frontiers of low-intensity focused ultrasound neuromodulation.Neuroscience · 2026