Development and validation of a deep learning-based automated Notch Width Index measurement system from anteroposterior knee radiographs.
Jingjing Tian, Ayato Saito, Takanori Iriuchishima, Sang Yang Lee, Tsuyoshi Kato
Graduate School of Informatics, Gunma University, Maebashi, Japan. Electronic address: aikoden00@gmail.com. · Graduate School of Informatics, Gunma University, Maebashi, Japan.
Key points
From the paper's conclusion- The method achieved moderate-to-good agreement with expert measurement while ensuring deterministic, examiner-independent reproducibility. Because it was never trained on surgeons' readings, this reflects reproduction of the geometric definition rather than overfitting. The principal barrier is segmentation under domain shift, not the algorithm; the method is best regarded as a reproducible standardization tool for routine anteroposterior views.
Abstract
BACKGROUND: The Notch Width Index (NWI), a radiographic marker of anterior cruciate ligament (ACL) injury risk, is poorly reproducible when measured manually. We developed a fully automated NWI system combining deep learning segmentation with geometric analysis. METHODS: A segmentation model (U-Net++/EfficientNet-B5) and a YOLOv8 laterality classifier were trained on 384 public images. Thirty-three anteroposterior knee radiographs were each measured twice by each of two surgeons. The fully automated method (D) was compared with both surgeons, and two semi-automated methods (B, C) with Surgeon 1 to isolate each processing stage, using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. The models were also applied without retraining to 500 external radiographs to assess feasibility and failure modes. RESULTS: Single-reading manual reliability was poor to moderate (ICC 0.475 and 0.562). The deterministic automated method agreed with both surgeons at ICC 0.525-0.756 (moderate to good); the semi-automated methods performed comparably (ICC 0.734 and 0.753). Segmentation reached a mean Dice coefficient of 0.975 ± 0.003, and processing was about 540 times faster than manual measurement. On the external dataset, segmentation degraded on osteoarthritic and low-quality images, so plausible values did not guarantee correct segmentation. CONCLUSION: The method achieved moderate-to-good agreement with expert measurement while ensuring deterministic, examiner-independent reproducibility. Because it was never trained on surgeons' readings, this reflects reproduction of the geometric definition rather than overfitting. The principal barrier is segmentation under domain shift, not the algorithm; the method is best regarded as a reproducible standardization tool for routine anteroposterior views.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development and validation of a U-Net-based deep learning model for automatic measurement of the hallux valgus angle and intermetatarsal angle.Clinical imaging · 2026
- U-Net-Based Automated Quality Control of Knee Radiographs: Dual-Center Validation and Clinical Intervention.Journal of imaging informatics in medicine · 2026
- Automated measurement of calcaneal inclination angle via partial semantic segmentation using U-Net.Diagnostic and interventional radiology (Ankara, Turkey) · 2026
- AUTOMATED KNEE CARTILAGE SEGMENTATION FOR T2 QUANTIFICATION USING HIGH-RESOLUTION MRI: VALIDATION IN THE NACOX ACL INJURY COHORT.Osteoarthritis imaging · 2026
- Accuracy and reliability of artificial intelligence-based automated measurement of hallux valgus-related angles on plain foot radiographs: a systematic reviewJournal of Orthopaedic Surgery and Research · 2026
- 3D QUANTITATIVE MEASUREMENTS OF JOINT SPACING BASED ON SEMI-AUTOMATIC AND AUTOMATIC SEGMENTATION, CONDUCTED 36 MONTHS APART, USING COMPUTED TOMOGRAPHY IMAGES.Osteoarthritis imaging · 2026