U-Net-Based Automated Quality Control of Knee Radiographs: Dual-Center Validation and Clinical Intervention.
Tianyi Xing, Yifan Guo, Hongbiao Sun, Wenwen Wang, Qi Chen, Xingyu Wei, Longlong Zhang, Yunmeng Wang,
School of Health Sciences and Engineering, University of Shanghai for Science and Technology, Shanghai, China. · School of Airspace Science and Engineering, Shandong University, Weihai, China.
Key points
From the paper's conclusion- We developed and validated an interpretable artificial intelligence (AI) framework for the automated QC of knee anteroposterior (AP) and lateral (LAT) radiographs and explored its clinical value.
Abstract
Knee radiography quality directly affects diagnostic accuracy. Current quality control (QC) mainly involves subjective, inefficient manual assessment, while existing automated tools lack sufficient clinical validation. We developed and validated an interpretable artificial intelligence (AI) framework for the automated QC of knee anteroposterior (AP) and lateral (LAT) radiographs and explored its clinical value. This two-stage retrospective study developed and validated U-Net models using 1600 adult single-knee AP and LAT radiographs from 800 patients at two centers. Anatomical segmentation and landmark localization yielded QC indices. Segmentation was evaluated using the Dice similarity coefficient (DSC); landmark localization using Euclidean error, normalized distance error (NDE), and percentage of correct keypoints (PCK); and QC performance using the intraclass correlation coefficient (ICC), sensitivity, and specificity. Separately, six radiographers received 4 weeks of AI-based feedback on 948 radiographs from 474 patients. The mean DSCs were 0.964 and 0.936 in the internal and external validation cohorts, respectively, and most of the ICCs exceeded 0.90. The mean AP localization errors were 13.52 pixels internally and 19.15 pixels externally, and the corresponding LAT values were 26.34 and 41.50 pixels, respectively. PCK@20% was 100.0%/99.4% for AP and 81.6%/61.8% for LAT in the internal/external cohorts. QC sensitivity ranged from 91.67% to 98.36%, and the specificity ranged from 89.13% to 99.10%. Post-feedback sensitivity showed exploratory numerical gains. Effect sizes ranged from 0.30 to 0.73. The proposed framework enables accurate, objective, and automated QC of knee radiographs, as demonstrated through dual-center validation. The workflow evaluation showed favorable exploratory trends in radiographer sensitivity, warranting further evaluation in prospective controlled studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quality assessment of radiographs through AI-driven feedback: A randomized comparative study on radiographer response in lateral knee radiographs.Radiography (London, England : 1995) · 2026
- Radiographic Projection Quality Score for the Knee (RPQS-Knee): Development and Reliability.Diagnostics (Basel, Switzerland) · 2026
- Development and validation of a deep learning-based automated Notch Width Index measurement system from anteroposterior knee radiographs.The Knee · 2026
- Downstream-Aware Automated QC of Images and AI-Generated Segmentations.Journal of imaging informatics in medicine · 2026
- Development and Validation of an Interpretable Deep Learning Model for Automated Kellgren-Lawrence Grading of Knee Osteoarthritis Using X-Ray Imaging.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
- Using of artificial intelligence to evaluate image quality for interproximal bone level assessment on bitewing radiographs.Imaging science in dentistry · 2026