Development and validation of a U-Net-based deep learning model for automatic measurement of the hallux valgus angle and intermetatarsal angle.
Woo Young Jang, Euddeum Shim, Nahyun Kim, Jungkwon Uhm, Dong Hun Suh, Ji Hun Park, Gi Won Choi
Department of Orthopaedic Surgery, Korea University Anam Hospital, Seoul, Republic of Korea. · Department of Radiology, Korea University Ansan Hospital, Ansan-si, Republic of Korea.
Key points
From the paper's conclusion- The proposed U-Net-based model provided accurate and reproducible automatic measurements of the HVA and IMA on weight-bearing dorsoplantar foot radiographs with high agreement with expert reference values. This approach may serve as a practical tool for standardized radiographic assessment of hallux valgus in clinical practice and research.
Abstract
PURPOSE: To develop and validate a U-Net-based deep learning model for the automated measurement of the hallux valgus angle (HVA) and intermetatarsal angle (IMA) on weight-bearing dorsoplantar foot radiographs and to compare model performance with expert reference values. METHODS: A total of 1227 weight-bearing dorsoplantar radiographs were obtained. The dataset was divided into training (n = 858), validation (n = 184), and testing (n = 185) datasets. Data augmentation was applied to the training set, yielding 10,296 samples. Six anatomical landmark points were labeled to define the axes of the proximal phalanges of the hallux, and of the first and second metatarsal. For temporal validation, 100 additional radiographs obtained at the same institution were evaluated. The U-Net-based model measurements were compared with the median values obtained from three independent experts (two foot and ankle surgeons and one musculoskeletal radiologist). RESULTS: In the temporal validation cohort, the AI model demonstrated high agreement with the expert reference standard. For the HVA, the mean absolute error (MAE) was 2.118° (95% CI: 1.770-2.475) and the intraclass correlation coefficient (ICC) was 0.961. For the IMA, the MAE was 0.966° (95% CI: 0.809-1.133) and the ICC was 0.919. Subgroup analysis revealed that the accuracy remained consistent across mild, moderate, and severe deformities. CONCLUSION: The proposed U-Net-based model provided accurate and reproducible automatic measurements of the HVA and IMA on weight-bearing dorsoplantar foot radiographs with high agreement with expert reference values. This approach may serve as a practical tool for standardized radiographic assessment of hallux valgus in clinical practice and research.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy and reliability of artificial intelligence-based automated measurement of hallux valgus-related angles on plain foot radiographs: a systematic reviewJournal of Orthopaedic Surgery and Research · 2026
- Automated measurement of calcaneal inclination angle via partial semantic segmentation using U-Net.Diagnostic and interventional radiology (Ankara, Turkey) · 2026
- Development and validation of a deep learning-based automated Notch Width Index measurement system from anteroposterior knee radiographs.The Knee · 2026
- Development and Validation of an Interpretable Deep Learning Model for Automated Kellgren-Lawrence Grading of Knee Osteoarthritis Using X-Ray Imaging.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
- Hallux valgus: The multidimensional perspective.Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons · 2026
- Automated 3D cephalometry: A lightweight V-net for landmark localization on CBCTComputerized Medical Imaging and Graphics · 2026