Using patient-specific computational fluid dynamics to assess intraprosthetic thrombus formation risk and guide relining after endovascular aneurysm repair.
Lysette V Scheepmaker, Paul van Schaik, Lennart van de Velde, Michel M P J Reijnen
Department of Surgery, Rijnstate, Arnhem, The Netherlands.
Key points
From the paper's conclusion- Therefore, CFD may provide valuable insights into the hemodynamic mechanisms underlying endograft thrombosis and may support personalized planning of relining strategies to reduce recurrent thromboembolic risk.
Abstract
UNLABELLED: A patient-specific computational fluid dynamics (CFD) analysis was performed to explore hemodynamic contributors of recurrent intraprosthetic thrombus and limb thrombosis in a patient after endovascular aneurysm repair (EVAR) and to investigate the potential of CFD to guide revision strategies. Key hemodynamic parameters, Time-averaged wall shear stress (TAWSS) and residence time (RT), were assessed showing a region with depressed TAWSS (below 0.1 Pa) at the site of intraprosthetic thrombus and a quasi-infinite RT of entrapped particles in that area. Next, CFD simulations tested a virtual limb-relining configuration, with geometric modifications resulting in improved TAWSS and RT. After mimicking the CFD-based relining with the implantation of an endograft a postprocedural analysis was performed. The postoperative results were in line with the prediction model and showed a 544% reduction in low area of TAWSS (<0.1 Pa) and a normalization of RT to 5 seconds. A contrast-enhanced computed tomography 1 year after stent placement showed a patent endograft without any signs of recurrent mural thrombus. Therefore, CFD may provide valuable insights into the hemodynamic mechanisms underlying endograft thrombosis and may support personalized planning of relining strategies to reduce recurrent thromboembolic risk. CLINICAL RELEVANCE: The second most common complication after endovascular aneurysm repair is thrombosis in one of the iliac stent graft limbs or distal thromboembolic events, which can cause acute limb ischemia. In some patients, these events persist even after a successful relining of the iliac stent graft with normal flow profiles on ultrasound. This report describes how computational fluid dynamics can identify flow pattern abnormalities and high residence time in a patient with recurring thromboembolic events after endovascular aneurysm repair placement, coinciding with the location of thrombus formation. Moreover, relining strategies can be virtually assessed in the patient's computer model to select a strategy that is expected to normalize the increased residence time.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient-specific hemodynamic evaluation of fenestrated physician-modified endografts in complex abdominal aortic aneurysmsFrontiers in Physics · 2026
- Computational fluid dynamics assessment of hemodynamic effects of catheter navigation during transcatheter aortic valve implantation.The International journal of artificial organs · 2026
- Predicting Post-TEVAR Endoleaks: A Pre-operative Hemodynamic Risk Factor from Patient-Specific Fluid-Structure Interaction Simulations.Annals of biomedical engineering · 2026
- Evaluation of Type I endoleak after endovascular aneurysm repair for abdominal aortic aneurysm using component quantification of energy loss: a preliminary feasibility study.Frontiers in cardiovascular medicine · 2026
- Position-Dependent Hemodynamics of Popliteal Artery Stent Grafts: The POPFLEX Study.Methods and protocols · 2026
- Computational modeling of thrombosis after transcatheter aortic valve implantation: A systematic review of hemodynamic and mechanical risk metrics.Computer methods and programs in biomedicine · 2026