Position-Dependent Hemodynamics of Popliteal Artery Stent Grafts: The POPFLEX Study.
Christos Chronis, Konstantinos Tzirakis, Nikolaos Kontopodis, Nikolaos Galanakis, Elias Kehagias, Christos V Ioannou
Vascular Surgery Department, Medical School, University of Crete, 71110 Heraklion, Greece. · Department of Mechanical Engineering, School of Engineering, Hellenic Mediterranean University, 71004 Heraklion, Greece.
Key points
From the paper's conclusion- Background: Endovascular exclusion of popliteal artery aneurysms (PAAs) with long covered stent-grafts is valuable for patients unfit for open surgery but is undermined by late stent thrombosis, even in fully scaffolded segments without kinking, a failure best clarified by computational fluid dynamics (CFD), which requires anatomically accurate 3D models-difficult to obtain in the mobile knee.
Abstract
Background: Endovascular exclusion of popliteal artery aneurysms (PAAs) with long covered stent-grafts is valuable for patients unfit for open surgery but is undermined by late stent thrombosis, even in fully scaffolded segments without kinking, a failure best clarified by computational fluid dynamics (CFD), which requires anatomically accurate 3D models-difficult to obtain in the mobile knee. Methods: In this prospective, single-centre study, consecutive patients undergoing endovascular PAA repair over 24 months (≥20 patients) underwent CT angiography in three knee positions (full extension, 45° and 90° flexion). Every treated limb was included, with limb as the unit of analysis. Images undergo a geometric pipeline: segmentation in 3D Slicer, then refinement in MeshLab, Meshmixer and VMTK. Meshes are converted to hexahedral volumes (ANSA Cadense) and simulated under pulsatile flow (ANSYS Fluent). Primary endpoints are time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI) and relative residence time (RRT) over the stented segment, plus the surface proportion meeting thrombogenic criteria; positions are compared via linear mixed-effects models with limb nested within patient. Results: The protocol reproducibly yields watertight, artefact-free models preserving physiological morphology and supporting TAWSS, OSI and RRT quantification across knee positions. Conclusions: This protocol standardizes generation of CFD-ready popliteal geometries, enabling positional analysis of stent thrombosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hemodynamic Effects of Renal Artery Orientation and Partial Ostial Coverage After Endovascular Aneurysm Repair: A 4D Flow MRI-Informed Computational Study.Bioengineering (Basel, Switzerland) · 2026
- Validation of individualized flow simulations for determining the pressure gradient in patients with renal artery stenosismedRxiv · 2026
- Computational Modeling of Thoracic Aortic Stent-Grafts: Bibliometric Analysis and Current TrendsComputation · 2026
- Computational hemodynamic analysis of idealized coronary arteries with cylindrical and conical stentsComputer Methods and Programs in Biomedicine · 2026
- Impact of stent graft geometry on hemodynamics in superior mesenteric artery reconstruction after fenestrated/branched endovascular aneurysm repair.Frontiers in bioengineering and biotechnology · 2026
- Patient-Specific Computational Fluid Dynamics of Pulmonary Arterial Hemodynamics in Dogs with and Without Pulmonic Stenosis.Animals : an open access journal from MDPI · 2026