Methods and protocols

Position-Dependent Hemodynamics of Popliteal Artery Stent Grafts: The POPFLEX Study.

Christos Chronis, Konstantinos Tzirakis, Nikolaos Kontopodis, Nikolaos Galanakis, Elias Kehagias, Christos V Ioannou

Vascular Surgery Department, Medical School, University of Crete, 71110 Heraklion, Greece. · Department of Mechanical Engineering, School of Engineering, Hellenic Mediterranean University, 71004 Heraklion, Greece.

Observational

Key points

From the paper's conclusion
  • Background: Endovascular exclusion of popliteal artery aneurysms (PAAs) with long covered stent-grafts is valuable for patients unfit for open surgery but is undermined by late stent thrombosis, even in fully scaffolded segments without kinking, a failure best clarified by computational fluid dynamics (CFD), which requires anatomically accurate 3D models-difficult to obtain in the mobile knee.

Abstract

Background: Endovascular exclusion of popliteal artery aneurysms (PAAs) with long covered stent-grafts is valuable for patients unfit for open surgery but is undermined by late stent thrombosis, even in fully scaffolded segments without kinking, a failure best clarified by computational fluid dynamics (CFD), which requires anatomically accurate 3D models-difficult to obtain in the mobile knee. Methods: In this prospective, single-centre study, consecutive patients undergoing endovascular PAA repair over 24 months (≥20 patients) underwent CT angiography in three knee positions (full extension, 45° and 90° flexion). Every treated limb was included, with limb as the unit of analysis. Images undergo a geometric pipeline: segmentation in 3D Slicer, then refinement in MeshLab, Meshmixer and VMTK. Meshes are converted to hexahedral volumes (ANSA Cadense) and simulated under pulsatile flow (ANSYS Fluent). Primary endpoints are time-averaged wall shear stress (TAWSS), oscillatory shear index (OSI) and relative residence time (RRT) over the stented segment, plus the surface proportion meeting thrombogenic criteria; positions are compared via linear mixed-effects models with limb nested within patient. Results: The protocol reproducibly yields watertight, artefact-free models preserving physiological morphology and supporting TAWSS, OSI and RRT quantification across knee positions. Conclusions: This protocol standardizes generation of CFD-ready popliteal geometries, enabling positional analysis of stent thrombosis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Position-Dependent Hemodynamics of Popliteal Artery Stent Grafts: The POPFLEX Study — Science Skim