Journal of vascular and interventional radiology : JVIR

Variation in Inferior Vena Cava Filter Retrieval Across U.S. Veterans Health Administration Facilities.

Premal Trivedi, Kevin Wells, Maria Puello Baron, Jonathan Lindquist, Harrison Bai, Robert Ryu, P Michael Ho

Department of Radiology, University of Colorado Anschutz Medical Campus. Aurora, CO. Electronic address: premal.trivedi@cuanschutz.edu. · Center of Innovation, U.S Department of Veterans Affairs.

Observational

Key points

From the paper's conclusion
  • IVC filter retrieval rates among Veterans remain low but exceed those reported in non-VA Medicare cohorts. Substantial inter-facility variation highlights opportunities to standardize structured device surveillance, with clear responsibility for follow-up.

Abstract

PURPOSE: Inferior vena cava (IVC) filters prevent pulmonary embolism (PE) in patients unable to receive anticoagulation but require prompt retrieval once protection is no longer needed. Despite national safety advisories and multidisciplinary guidelines, IVC filter retrieval remains low in the United States. How much variation underlies low retrieval across Veterans Affairs (VA) facilities has not been studied. MATERIALS AND METHODS: This retrospective longitudinal cohort study included Veterans who underwent IVC filter implantation at VA facilities between 2016 and 2023. Veterans who died within 90 days of implantation or lacked 1 year of follow-up were excluded. IVC filter implantation and retrieval were identified using procedure codes in the VA Corporate Data Warehouse. A multivariable Bayesian mixed-effects model estimated risk-adjusted retrieval rates across facilities. Logistic regression was performed to identify specific patient- and facility-level factors associated with non-retrieval. RESULTS: Among 3,670 Veterans (median age 69 years; 95.9% male), retrieval occurred in 10.5% within 90 days, 22.2% within 1 year, and 24.7% overall. Risk-adjusted 1-year retrieval varied widely across facilities: 0-60%. Older veteran age (> 75 years), facility academic affiliation, and Southern census region were associated with lower retrieval, whereas implantation at higher-complexity facilities and pre-COVID years were associated with higher retrieval. CONCLUSIONS: IVC filter retrieval rates among Veterans remain low but exceed those reported in non-VA Medicare cohorts. Substantial inter-facility variation highlights opportunities to standardize structured device surveillance, with clear responsibility for follow-up.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Variation in Inferior Vena Cava Filter Retrieval Across U.S. Veterans Health Administration Facilities — Science Skim