Adverse event reporting patterns for endodontic files in the FDA MAUDE database: a postmarket surveillance analysis, 2015-2025.
Süha Alpay
Department of Endodontics, Faculty of Dentistry, Istanbul Aydın University, Istanbul, Türkiye. Electronic address: salpay@aydin.edu.tr.
Key points
From the paper's conclusion- MAUDE endodontic-file reports show reporting pattern differences, not comparative clinical risk. The principal signal was stainless-steel hand-file-dominated injury/separation reporting, with no IC025-supported modern HT-M-Wire signal. Manufacturer concentration and absent use denominators require triangulation with denominator-based data.
Abstract
INTRODUCTION: Endodontic files have not been specifically characterized in the FDA Manufacturer and User Facility Device Experience (MAUDE) database. We characterized adverse-event reporting patterns for heat-treated NiTi (HT), conventional austenitic NiTi (CONV) and manual hand files from 2015-2025 and evaluated whether MAUDE can support alloy-level clinical-risk inference. METHODS: MAUDE reports filed from 01 January 2015 to 31 December 2025 for File, Pulp Canal, Endodontic were retrieved through the openFDA API and classified a priori by brand into HT, CONV and HAND. Groups were compared using χ2/Fisher-Freeman-Halton tests, Cramér's V, Reporting Odds Ratios (RORs) and shrinkage observed-to-expected Information Components with Gamma lower limits (IC025). A Break-excluded separation/fracture composite was the key secondary endpoint. RESULTS: Of 2,824 retrieved reports, 2,666 were analysed. HAND reports showed more injury events than HT reports (9.8% vs 3.0%; p < 0.001; Cramér's V = 0.112). Because HAND reports were almost entirely stainless-steel hand files (297/307, 96.7%), this represents a stainless-steel hand-file reporting signal rather than a manual-instrumentation signal. The Break-excluded composite supported this signal (ROR 3.04; IC025 0.55). A borderline Modern HT-M-Wire Material Separation contrast was not supported by Bayesian shrinkage. Overall, 87.2% of reports originated from Dentsply-affiliated entities. CONCLUSIONS: MAUDE endodontic-file reports show reporting pattern differences, not comparative clinical risk. The principal signal was stainless-steel hand-file-dominated injury/separation reporting, with no IC025-supported modern HT-M-Wire signal. Manufacturer concentration and absent use denominators require triangulation with denominator-based data.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of the accuracy, completeness, and compliance of current summary reporting of adverse events to the Food and Drug Administration using the manufacturer and user facility device experience (MAUDE) database: cross sectional study.BMJ (Clinical research ed.) · 2026
- Post-market safety signals of energy-based surgical devices: a cross-specialty disproportionality analysis of the FDA MAUDE database with robotic-platform validation and regulatory triangulation, 2015-2025.Journal of robotic surgery · 2026
- Adverse events of implantable breast tissue and biopsy-site markers: a cross-sectional analysis of the FDA MAUDE database (2010-2025).Clinical imaging · 2026
- All-Inside Meniscus Repair Systems Failure Analysis Shows Device-Related Adverse Events Differ by Device Design Type and Show Varied Reporting Delays by Manufacturer.Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2026
- Adverse events and device failures of the transoral incisionless fundoplication system: a MAUDE database analysis.Surgical endoscopy · 2026
- Unveiling the true burden of endodontic adverse events in academic settings: A five-year multivariate risk analysis.Revista cientifica odontologica (Universidad Cientifica del Sur) · 2026