Deformation and Fracture of NiTi Instruments Using Adaptive Reciprocation Intelligent or Fixed-Angle Reciprocation Settings.
Felipe G Belladonna, Victor T L Vieira, Marco Simões-Carvalho, Carlos Garcia Puentes, Alejandro Jaime, Emmanuel J N L Silva
Department of Endodontics, School of Dentistry, Fluminense Federal University (UFF), Niterói, Brazil. · Department of Endodontics, School of Dentistry, Rio de Janeiro Federal University (UFRJ), Rio de Janeiro, Brazil.
Key points
From the paper's conclusion- The ARI setting delayed visible deformation and markedly increased the number of simulated canals prepared before fracture of One RECI instruments, without significantly affecting fractured-fragment length.
Abstract
INTRODUCTION: To compare the canal number at first visible deformation, the number of simulated canals completely prepared before fracture, and fractured-fragment length of One RECI instruments operated using fixed-angle conventional reciprocation or the Adaptive Reciprocation Intelligent (ARI) setting. METHODS: Twenty-six One RECI instruments were allocated to conventional reciprocation or ARI groups (n = 13). Fixed-angle reciprocation used parameters of 170° counterclockwise/60° clockwise, 4.0 Ncm, and 400 rpm. ARI initially used the same parameters but automatically changed to 90° counterclockwise/30° clockwise, 0.4 Ncm and 500 rpm when resistance to instrument advancement was detected. A single experienced operator repeatedly prepared simulated canals in transparent resin blocks until instrument fracture. Each canal was prepared using successive sequences of three gentle in-and-out pecking movements, with instrument cleaning and inspection, canal irrigation with 5 mL of distilled water, and recapitulation with a size 15 K-file between sequences, until the working length was reached. The canal number at first visible deformation and the number of canals completely prepared before fracture were recorded. Fractured-fragment length was measured digitally from the instrument tip to the fracture line. Groups were compared using two-sided Mann-Whitney U tests (α = 0.05). RESULTS: First visible deformation was detected at a significantly higher simulated canal number with ARI than with conventional reciprocation (median [interquartile range], 3 [1-5] versus 1 [1-2]; P = 0.037). ARI also increased the number of canals completely prepared before fracture (20 [18-30] versus 6 [5-11]; P < 0.001). Fractured-fragment length did not differ significantly between ARI and conventional reciprocation (14.15 [11.65-14.43] mm versus 13.77 [13.61-14.51] mm; P = 0.644). CONCLUSIONS: The ARI setting delayed visible deformation and markedly increased the number of simulated canals prepared before fracture of One RECI instruments, without significantly affecting fractured-fragment length.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Surface alterations of the MicroMega One RECI reciprocating instrument under two kinematics: A scanning electron microscopy evaluation.Journal of clinical and experimental dentistry · 2026
- Comparative evaluation of shaping ability of EdgeOne-R Utopia, One Reci, and WaveOne Gold in severely curved simulated root canals: an in vitro study.BMC oral health · 2026
- Comparative In Vitro Assessment of Original Reciproc® Blue Instruments vs. Two Replicas: Mechanical Characteristics, Safety, and Efficacy AnalysisOral · 2026
- Cyclic Fatigue Resistance and Fractured Fragment Length of Three NiTi Rotary Systems: An In Vitro ComparisonOral · 2026
- A Comparative Evaluation of the Cyclic Fatigue Resistance of Three Nickel-Titanium Rotary File Systems in a Simulated Curved Canal: An In Vitro Study.Cureus · 2026
- Influence of radius of curvature on the cyclic fatigue resistance of three NiTi systems at simulated body temperatureBMC Oral Health · 2026