Dual-phase systolic and diastolic cardiac diffusion tensor imaging using higher order motion compensation spin echo sequences at 300 mT/m gradient strength.
Maryam Afzali, Irvin Teh, Sam Coveney, Lars Mueller, Isaac Watson, May Lwin, Sarah Jones, Fabrizio Fasano,
Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, United Kingdom; Cardiff University Brain Research Imaging Centre (CUBRIC), School of Psychology, Cardiff University, Cardiff, United Kingdom; Division of Cardiovascular Sciences and the British Heart Foundation Centre of Research Excellence, University of Leicester, National Institute of Health and Care Research Biomedical Research Centre Leicester, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, United Kingdom. · Biomedical Imaging Science Department, Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, United Kingdom.
Key points
From the paper's conclusion- This study demonstrates the feasibility of dual-phase SE-based cDTI techniques enabled by 300 mT/m gradients. This method will allow reliable quantification of myocardial microstructural changes between systole and diastole and represents a step towards clinical translation of dynamic cDTI.
Abstract
BACKGROUND: Cardiac diffusion tensor imaging (cDTI) provides unique insights into myocardial microstructure and its dynamic changes during the cardiac cycle. However, motion sensitivity remains a major obstacle for spin echo (SE)-based approaches, restricting most implementations to a relatively narrow low-motion window near peak systole. PURPOSE: To establish whether higher-order motion-compensated (up to 6th order) diffusion gradients beyond standard second order motion compensation (M2) on a magnetic resonance imaging (MRI) system with a maximum gradient strength of 300 mT/m improve SE-based cDTI techniques for both systolic and diastolic acquisitions. METHODS: Ten healthy volunteers underwent free-breathing, cardiac-gated SE-cDTI acquisitions in systole and in diastole using diffusion gradients with up to second- (M2), fourth- (M4), and sixth-order (M6) motion compensation. Success rate (percentage of left ventricular voxels with (1.1 < MD < 1.9) × 10-3mm2∕s) and diffusion measures including mean diffusivity, fractional anisotropy, helix angle, and secondary eigenvector angle were quantified and compared between both cardiac phases. RESULTS: Second-order motion compensation was sufficient for systolic cDTI, whereas fourth-order motion compensation was required for successful diastolic acquisitions in all participants. Mean diffusivity values in systole were (1.53 ± 0.06), (1.60 ± 0.07), and (1.62 ± 0.06) × 10-3mm2∕s for M2, M4, and M6 respectively, and in diastole were (2.26 ± 0.67), (1.73 ± 0.19), and (1.71 ± 0.12) × 10-3mm2∕s. No significant differences in cDTI-derived parameters were observed between M4 and M6 for systolic and diastolic acquisitions. CONCLUSION: This study demonstrates the feasibility of dual-phase SE-based cDTI techniques enabled by 300 mT/m gradients. This method will allow reliable quantification of myocardial microstructural changes between systole and diastole and represents a step towards clinical translation of dynamic cDTI.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Improved Precision of High b‐Value In Vivo Cardiac Diffusion Tensor Imaging on a Commercial Ultrahigh Performance Gradient MRI SystemNMR in Biomedicine · 2026
- Balancing Directions and Averages for Cardiac Diffusion Tensor Imaging Using a Moderate Gradient Performance SystemNMR in Biomedicine · 2026
- High-spatial resolution, high-quality white matter tractography using DTI with dynamic slice-by-slice B0 shimming in a head-only high-gradient performance 3T MRI scannerarXiv · 2026
- Motion Mitigation Techniques for Abdominal and Cardiac MR ImagingJournal of Magnetic Resonance Imaging · 2025
- Camera-Seismocardiography Based Cardiac Triggering for Magnetic Resonance Imaging: A Prospective Study.IEEE journal of biomedical and health informatics · 2026
- Microstructural assessment of hypertrophic cardiomyopathy with preserved left ventricular ejection fraction using second-order motion-compensated spin echo diffusion tensor cardiovascular magnetic resonance imaging.European journal of radiology · 2026