High-spatial resolution, high-quality white matter tractography using DTI with dynamic slice-by-slice B0 shimming in a head-only high-gradient performance 3T MRI scanner
Jerome J. Maller, Patricia Lan, Sherry Huang, Chitresh Bhushan, Xinzeng Wang, Ante Zhu, Vincent A. Magnotta
Key points
From the paper's conclusion- In conclusion, DySiBo in conjunction with DTI requiring 10 diffusion tensor directions is sufficient to generate data with high enough SNR and angular resolution to resolve crossing fibers and produce high quality WM tractography in brain regions typically affected by susceptibility-induced artefacts.
Abstract
Data from conventional diffusion tensor imaging (DTI) using single-shot echo planar imaging (SS-EPI) acquisition are substantially influenced by magnetic field inhomogeneities (delta B0), which result in image distortion and signal dephasing. Multi-shot EPI can mitigate the delta B0-induced artifacts but at the cost of increased scan time. Recent brain tissue-selective, dynamic slice-by-slice B0 shimming techniques have demonstrated effective reduction of local delta B0 in the brain. When combined with DTI utilizing an echo-planar imaging (EPI) read-out, image distortion and signal dephasing are significantly reduced. The purpose of our study was to assess the impact of DTI with dynamic slice-by-slice B0 shimming technique (DySiBo) on white matter (WM) tractography. We retrospectively analyzed DTI datasets using SS-EPI and Multi-shot EPI with 2 shots (MS-2shot-EPI) readout at two spatial resolutions (1x1x2mm3 and 2x2x2mm3) with and without DySiBo. WM tractography was generated and inspected to examine the impact upon regions typically affected by delta B0-induced artefacts. We found more WM streamlines were generated in the DTI datasets with DySiBo in regions conventionally impacted by delta B0-induced in EPI images, including the brainstem, temporal and frontal lobes. DySiBo substantially improved the generation of WM streamlines in DTI-based tractography at both in-plane resolutions. In conclusion, DySiBo in conjunction with DTI requiring 10 diffusion tensor directions is sufficient to generate data with high enough SNR and angular resolution to resolve crossing fibers and produce high quality WM tractography in brain regions typically affected by susceptibility-induced artefacts. This has implications for quantitative WM microstructural indices and clinical evaluation of WM tracts in patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep Learning-Based Distortion Correction for Brain Diffusion-weighted Imaging: A Prospective Comparison With Single-shot and Readout-segmented Echo-planar Imaging.Investigative radiology · 2026
- ESR Essentials: diffusion-weighted MRI—practice recommendations by the European Society for Magnetic Resonance in Medicine and BiologyEuropean Radiology · 2025
- Does Denoising Reduce Cross-Vendor Variability in Diffusion MRI? A Travelling Heads EvaluationbioRxiv · 2026
- Longitudinal quantitative streamline tractography: Robust estimation of white matter connectivity differences.Imaging neuroscience (Cambridge, Mass.) · 2026
- AI-based reconstruction from low-resolution acquisitions for diffusion MRI: evaluation of FOD similarity.Radiological physics and technology · 2026
- Deep Resolve Boost in 2D MRI for Neuroradiology: A Comparative Evaluation of Diagnostic Gains and Potential RisksAmerican Journal of Neuroradiology · 2025