Improved Precision of High b‐Value In Vivo Cardiac Diffusion Tensor Imaging on a Commercial Ultrahigh Performance Gradient MRI System
Moses Cook, Thomas Garrett, Danielle Kara, Yuchi Liu, Owen Lockwood, Dingheng Mai, Shi Chen, Arwa Younis,
Key points
From the paper's conclusion- This study compared cDTI precision at b = 500 and b = 1000 s/mm 2 on a commercially available 3 T MRI system equipped with ultrahigh‐performance gradients.
Abstract
Cardiac diffusion tensor imaging (cDTI) enables non‐invasive assessment of myocardial microstructure, but clinical implementation remains limited by low signal‐to‐noise ratio (SNR) and the prolonged echo times associated with higher diffusion weighting. Ultrahigh‐performance gradients may enable higher b ‐values while maintaining clinically feasible acquisition times. This study compared cDTI precision at b = 500 and b = 1000 s/mm 2 on a commercially available 3 T MRI system equipped with ultrahigh‐performance gradients. Twenty healthy volunteers and six patients with cardiac amyloidosis (CA) underwent cDTI at b = 500 and b = 1000 s/mm 2 using identical acquisition parameters except for diffusion encoding strength and echo time. Mean diffusivity (MD), fractional anisotropy (FA), and helix angle transmurality (HAT) were calculated. SNR, geometric distortion, and measurement uncertainty were also assessed using bootstrap analysis. Paired statistical comparisons were performed between diffusion weightings in healthy volunteers. In healthy volunteers, b = 1000 s/mm 2 produced significantly lower MD (1.42 ± 0.05 vs. 1.51 ± 0.05 × 10 −3 mm 2 /s, p < 0.001) and FA (0.30 ± 0.02 vs. 0.32 ± 0.01, p < 0.001) and greater HAT magnitude (−0.86 ± 0.14 vs. −0.75° ± 0.18°/% transmural depth, p < 0.01) compared with b = 500 s/mm 2 . Spatial variance was significantly reduced at b = 1000 s/mm 2 for MD, FA, and HAT. Uncertainty was reduced for MD, FA, and the first eigenvector. In CA, MD was higher and FA and HAT magnitude were lower than in healthy volunteers at both b ‐values. In sum, b = 1000 s/mm 2 cDTI demonstrated reduced spatial heterogeneity and lower measurement uncertainty compared with b = 500 s/mm 2 despite reduced SNR. Higher diffusion weighting may therefore improve the precision and microstructural specificity of cardiac diffusion measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-phase systolic and diastolic cardiac diffusion tensor imaging using higher order motion compensation spin echo sequences at 300 mT/m gradient strength.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2026
- Balancing Directions and Averages for Cardiac Diffusion Tensor Imaging Using a Moderate Gradient Performance SystemNMR in Biomedicine · 2026
- The effects of a gadolinium-based contrast agent on cardiac diffusion tensor imagingEuropean Heart Journal · 2026
- Regional myocardial microstructural assessment in aortic stenosis by cardiac diffusion tensor imagingEuropean Heart Journal · 2026
- Microstructural assessment of hypertrophic cardiomyopathy with preserved left ventricular ejection fraction using second-order motion-compensated spin echo diffusion tensor cardiovascular magnetic resonance imaging.European journal of radiology · 2026
- Age and sex specific normal reference values for 3T spin echo cardiac diffusion tensor imaging in 104 healthy subjectsEuropean Heart Journal · 2026