Journal of the mechanical behavior of biomedical materials

Comparative evaluation of the wear of natural teeth opposing CAD-CAM milled zirconia and BioHPP: An in vitro study.

Aman Zubair, G Lambodaran, S Vigneswaran, H Annapoorni

Department of Prosthodontics, Meenakshi Ammal Dental College and Hospital, Meenakshi Academy of Higher Education and Research, Chennai, India. · Department of Prosthodontics, Meenakshi Ammal Dental College and Hospital, Meenakshi Academy of Higher Education and Research, Chennai, India. Electronic address: drlambo.prostho@madch.edu.in.

Preclinical · n=12

Key points

From the paper's conclusion
  • Within the limitations of this in vitro model, CAD/CAM-milled zirconia produced greater wear of the opposing natural tooth than BioHPP, which showed a more enamel-conservative wear pattern; these findings support cautious material selection when antagonist tooth preservation is a clinical priority, though laboratory results warrant cautious extrapolation to clinical performance.

Abstract

This study compared the two-body wear of natural teeth opposing computer-aided design/computer-aided manufacturing (CAD/CAM)-milled zirconia versus biocompatible high-performance polymer (BioHPP) in vitro. Twenty-four disc-shaped specimens (10 mm diameter, 2 mm thickness) were divided into two groups (n = 12): CAD/CAM-milled zirconia (3Y-TZP) and CAD/CAM-milled BioHPP. Each disc was antagonized by an extracted, caries-free human premolar embedded in acrylic resin, and two-body wear was simulated under a constant vertical load of 5 kg (49 N) for 10,000 cycles, with artificial saliva applied intermittently to maintain a moist testing environment. Tooth specimens were digitally scanned and weighed before and after testing; scan volume, scan height, weight loss, and wear percentage were compared between groups using paired and independent-samples t-tests. Teeth opposing zirconia showed significantly greater reductions in scan height and significantly greater weight loss (0.002 ± 0.005 g vs 0.0007 ± 0.0001 g; P = .001) and wear percentage (0.023 ± 0.006% vs 0.008 ± 0.0015%; P = .001) than teeth opposing BioHPP, while whole-specimen scan volume decreased similarly in both groups (P = .83). Within the limitations of this in vitro model, CAD/CAM-milled zirconia produced greater wear of the opposing natural tooth than BioHPP, which showed a more enamel-conservative wear pattern; these findings support cautious material selection when antagonist tooth preservation is a clinical priority, though laboratory results warrant cautious extrapolation to clinical performance.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers