Evaluation of topography, color stability, and fracture resistance of prefabricated primary crowns with different material compositions: an in vitro study.
Maii Mohamed, Aiah A El-Rashidy, Mohamed Amr ElKhashab, Omar Shaalan, Osama Ibrahim El Shahawy
Pediatric Dentistry Department, Faculty of Dentistry, Cairo University, Cairo, 11553, Egypt. maii.ali@dentistry.cu.edu.eg. · Biomaterials Department, Faculty of Dentistry, Cairo University, Cairo, 11553, Egypt.
Key points
From the paper's conclusion- HPCs exhibited greater color change than ZRCs, while their fracture resistance was not significantly different from that of ZRCs.
Abstract
BACKGROUND: Full coverage of primary teeth with stainless steel crowns (SSC) has shown limited esthetic acceptance. Few studies have investigated hybrid polymer-based crowns (HPC) under critical loading in comparison with SSC and prefabricated zirconia crowns (ZRC) in vitro. AIM: This in vitro study compared wear, wear of antagonist teeth, vertical marginal gap, fracture resistance, and color stability of HPCs with those of SSCs and ZRCs. METHODS: Fifteen 3D-printed identical dies were fabricated to receive prefabricated crowns, which were divided into 3 groups: (1) stainless steel (SSCs), (2) zirconia (ZRCs), and (3) hybrid polymer-based (HPCs). Vertical marginal gap was assessed by measuring the vertical distance between the crown and die margins before and after thermomechanical ageing to simulate 1 year. Crowns were optically scanned to analyse the average surface roughness. Wear assessment via Geomagic software was performed for crowns and antagonist teeth. Color change was evaluated via digital imaging method. Fracture resistance was assessed by applying a load until fracture, then failure mode was evaluated. Data were assessed with Kolmogorov-Smirnov and Shapiro-Wilk tests. Intergroup comparisons were performed using one-way ANOVA and Tukey's post hoc test; intragroup comparisons used paired t-tests, and categorical data analysed with chi-square test. RESULTS: Statistically significant differences were found in the vertical marginal gap, where HPCs had the highest value, followed by ZRCs and SSCs (P < 0.001); however, these values were all within clinically acceptable range. There was no statistically significant difference in surface roughness (P > 0.016). SSCs presented the greatest amount of wear, followed by HPCs and ZRCs (P < 0.001). Hybrid polymer-based crowns showed the greatest color change, followed by ZRCs (P < 0.001). HPCs showed the greatest color change (P < 0.001). SSCs had the highest fracture resistance (1713.00 ± 181.84 N), whereas HPCs (980.72 ± 132.41 N) and ZRCs (1039.63 ± 209.21 N) did not differ significantly. HPCs and SSCs exhibited surface deformation and microperforations, whereas ZRCs exhibited fracture. CONCLUSIONS: HPCs, ZRCs, and SSCs had vertical marginal gap values within the clinically acceptable range, and no significant differences were found in surface roughness between groups. HPCs showed lower crown wear than SSCs and lower antagonist wear than ZRCs and SSCs. HPCs exhibited greater color change than ZRCs, while their fracture resistance was not significantly different from that of ZRCs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative evaluation of hybrid resin polymer crowns versus preformed metal crowns in primary molars of children aged 3-7 years: a prospective parallel-group clinical study.European archives of paediatric dentistry : official journal of the European Academy of Paediatric Dentistry · 2026
- Comparative evaluation of periodontal biocompatibility of pediatric crowns using clinical parameters and GCF biomarkers.BMC oral health · 2026
- Prefabricated Zirconia Crowns in Primary Molars: A Randomised Split‐Mouth Clinical TrialInternational Journal of Clinical Practice · 2026
- In vitro evaluation of Streptococcus mutans adhesion on prefabricated primary crowns using colony-forming unit analysis and scanning electron microscopy: a pilot study.BMC research notes · 2026
- Documented Failure Patterns of Prefabricated Zirconia Crowns on Pulpectomized Maxillary Primary Incisors in Children Treated Under General Anesthesia: A Retrospective Study.Children (Basel, Switzerland) · 2026
- Clinical outcomes of hybrid resin polymer crowns compared with stainless steel and zirconia crowns in primary molars: A systematic review and meta-analysis of randomized controlled trials.Journal of the American Dental Association (1939) · 2026