Journal of ISAKOS : joint disorders & orthopaedic sports medicine

Ultracongruent inserts are associated with a higher Knee Injury and Osteoarthritis Outcome Score for Joint Replacement at 18 months than posterior-stabilized inserts after primary total knee arthroplasty: A matched cohort study.

Jorge Isla, Pablo Escudero, Agustín Teneo, Hernán Salas, José Aracena, Sebastián Sanchez, Héctor Hermosilla, Marcelo Castillo,

Department of Traumatology, Clinica Alemana de Santiago, Santiago, Chile; Department of Traumatology, Hospital del Salvador, Santiago, Chile. · Resident of Traumatology, Hospital del Salvador, Santiago, Chile.

Observational · n=200

Key points

From the paper's conclusion
  • Patients who received surgeon-selected UC inserts had higher 18-month functional scores than those who received PS inserts. However, insert selection was influenced by surgeon preference and intraoperative assessment, and the principal biomechanical determinants of that decision were not available for matching or adjustment. The observed association may therefore reflect differences in case complexity rather than insert design alone and should not be interpreted as evidence of comparative superiority.

Abstract

PURPOSE: The purpose of the study is to compare 18-month functional outcomes and preoperative-to-postoperative improvement in the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR) between ultracongruent (UC) and posterior-stabilized (PS) inserts in patients undergoing primary total knee arthroplasty (TKA) with posterior cruciate ligament sacrifice using the same implant system. METHODS: This retrospective matched cohort study included patients who underwent primary TKA between 2017 and 2022 using the Stryker Triathlon® system. After matching, 200 patients were analyzed: 100 treated with UC inserts and 100 with PS inserts. Groups were matched by sex, age, body mass index, follow-up duration, and Kellgren-Lawrence grade. The primary outcome was KOOS-JR at 18 months. Preoperative KOOS-JR was recorded to calculate absolute improvement. Secondary outcomes included the Knee Society Score knee component (KSS-Knee) and the function component (KSS-Function). Multivariable linear regression was performed to adjust for potential confounders. RESULTS: At 18 months, the UC group demonstrated higher KOOS-JR scores than the PS group (mean ± standard deviation, 86.1 ± 9.2 vs 70.3 ± 9.2 points; mean difference, 15.8 points; 95% confidence interval [CI], 13.2 to 18.4; p < 0.001). KSS-Knee and KSS-Function scores also favored UC inserts. In adjusted analyses, UC insert use remained associated with higher postoperative KOOS-JR and greater KOOS-JR improvement. CONCLUSION: Patients who received surgeon-selected UC inserts had higher 18-month functional scores than those who received PS inserts. However, insert selection was influenced by surgeon preference and intraoperative assessment, and the principal biomechanical determinants of that decision were not available for matching or adjustment. The observed association may therefore reflect differences in case complexity rather than insert design alone and should not be interpreted as evidence of comparative superiority. LEVEL OF EVIDENCE: III.

Read the paper