Immediate functional trade-offs in hand strength with static wrist orthosis use in carpal tunnel syndrome.
Ümit Uğurlu
Bezmialem Vakıf University, Faculty of Health Sciences, Department of Occupational Therapy, İstanbul, Türkiye; İstanbul University-Cerrahpaşa, Cerrahpaşa Faculty of Medicine, Department of Internal Medicine, Division of Rheumatology, İstanbul, Türkiye. Electronic address: uugurlu@bezmialem.edu.tr.
Key points
From the paper's conclusion- SWO use produces immediate reductions in hand strength in CTS, greatest for GS, with descriptive differences across pinch measures. Hand therapists should consider the functional trade-off between wrist stabilization and force-generating capacity when prescribing SWOs and provide individualized, task-specific guidance for daily manual activities.
Abstract
BACKGROUND: Static wrist orthoses (SWOs) are commonly prescribed for carpal tunnel syndrome (CTS) to maintain neutral wrist alignment and reduce provocative wrist postures. However, their immediate effects on hand strength during manual performance remain unclear. PURPOSE: To quantify the immediate effects of SWO use on multiple domains of hand strength in individuals with CTS. STUDY DESIGN: Clinical measurement, cross-sectional, within-subject study. METHODS: Sixty-five patients with bilateral CTS completed standardized hand strength testing under orthosis-free and SWO conditions. Grip strength (GS), grip pressure (GP), lateral pinch (LP), palmar pinch (PP), and tip-to-tip pinch (TTP) were assessed in both hands with counterbalanced test order. Each outcome was analyzed using a 2 × 2 repeated-measures ANOVA with condition and hand as within-subject factors; paired t tests quantified within-hand changes and Cohen's dz effect sizes. RESULTS: SWO use significantly reduced all hand strength outcomes in both hands. GS showed the largest relative reductions, decreasing by 45.8% in the dominant hand and 48.2% in the nondominant hand, with very large effect sizes. GP showed smaller reductions of 7.7 and 8.0%, respectively, with large effect sizes. Pinch reductions varied descriptively: LP showed the smallest reductions, whereas PP and TTP showed larger reductions in both hands. Mean GS decreases were 11.34 kg in the dominant hand and 10.90 kg in the nondominant hand. All paired comparisons were significant (p < 0.01). CONCLUSIONS: SWO use produces immediate reductions in hand strength in CTS, greatest for GS, with descriptive differences across pinch measures. Hand therapists should consider the functional trade-off between wrist stabilization and force-generating capacity when prescribing SWOs and provide individualized, task-specific guidance for daily manual activities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ergonomically designed arch-integrated hand orthosis for computer typing to reduce the risk of carpal tunnel syndrome.Journal of hand therapy : official journal of the American Society of Hand Therapists · 2026
- Diagnostic Performance of Ultrasonographic Median Nerve Cross-Sectional Area for Carpal Tunnel Syndrome in Wheelchair Users With Spinal Cord Injury.American journal of physical medicine & rehabilitation · 2026
- Wrist and Thumb Kinematics During Sustained Smartphone Typing in Patients with Carpal Tunnel Syndrome: A Cross-Sectional Comparative Study.Journal of clinical medicine · 2026
- Shear Wave Elastography of the Abductor Pollicis Brevis in Carpal Tunnel Syndrome: Relationship with Quantitative Motor Unit Potential and Nerve Conduction Parameters.Journal of clinical medicine · 2026
- Design and Finite Element Evaluation of a Customized 3D-Printed Wrist-to-Finger Orthosis Targeting Carpal Tunnel Pressure Reduction.Polymers · 2026
- Monitoring Regional Inter-Sensor Sagittal Tilt in Orthoses Using a Wearable Sensor System.Bioengineering (Basel, Switzerland) · 2026