From the paper's conclusion- Background/Objectives: We examined the association between shear wave elastography (SWE) of the abductor pollicis brevis (APB) and quantitative motor unit potential (MUP) parameters in carpal tunnel syndrome (CTS), using the ulnar-innervated abductor digiti minimi (ADM) as a reference muscle.
Abstract
Background/Objectives: We examined the association between shear wave elastography (SWE) of the abductor pollicis brevis (APB) and quantitative motor unit potential (MUP) parameters in carpal tunnel syndrome (CTS), using the ulnar-innervated abductor digiti minimi (ADM) as a reference muscle. Methods: In this prospective cross-sectional study, 73 patients with electrodiagnostically confirmed CTS (125 hands) and 37 healthy controls (69 hands) underwent SWE of the median nerve, APB, and ADM. Quantitative MUP analysis of the APB was performed in 65 hands with moderate or severe CTS. Both hands were included and analysed using mixed-effects models with participant as a random intercept; correlations were corrected using the Benjamini-Hochberg procedure. Results: The median nerve cross-sectional area, Young's modulus, and shear wave velocity were higher in CTS hands than in controls (all p < 0.001), as were APB Young's modulus (difference 2.85 kPa, 95% CI 0.46 to 5.24; p = 0.020) and shear wave velocity (p = 0.027). The ADM measurements and the within-hand APB/ADM ratio did not differ significantly. APB stiffness did not correlate with any MUP or motor conduction parameter. Weak correlations with sensory distal latency and sensory conduction velocity did not survive correction for multiple comparisons. Conclusions: Increased stiffness of the median nerve and the APB in CTS was not accompanied by a difference in the ulnar-innervated ADM, but the within-hand APB/ADM ratio did not differ either, so anatomical specificity was not established. Increased APB stiffness represented a group-level mechanical change that, in moderate-to-severe CTS, did not track neurogenic motor unit remodelling as measured by needle electromyography, and its clinical role remains to be defined.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic accuracy of ultrasound in carpal tunnel syndrome: analysis of established and novel parametersBritish Journal of Radiology · 2025
- Ultrasound Shear Wave Elastography of Ulnar Nerve and Flexor Carpi Ulnaris in Young Adults: A Preliminary Observation.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026
- Ultrasound-Based Severity Stratification in Carpal Tunnel Syndrome: Median Nerve Cross-Sectional Area for Distinguishing Severe from Moderate Disease.Diagnostics (Basel, Switzerland) · 2026
- Shear-Wave Elastography in Musculoskeletal Pain: Current Evidence and Clinical Applications for Tissue Stiffness Assessment.Medicina (Kaunas, Lithuania) · 2026
- Layer-Specific Shear Wave Elastography Reveals the Tissue Origin of MyotonPRO-Derived Muscle Stiffness.Diagnostics (Basel, Switzerland) · 2026
- Assessment of ulnar nerve viscoelasticity in patients with cubital tunnel syndrome using a novel ultrasound technique.Skeletal radiology · 2026