Novel swirl core nozzle enhances atomization and suppresses hazardous byproducts of next-generation fire extinguishing agents.
Zhilei Yu, Junchao Zhao, Haibin Dong, Song Lu, Guohui Li, Xuelei Xian, Heping Zhang
State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, PR China. · State Key Laboratory of Fire Science, University of Science and Technology of China, Hefei, PR China. Electronic address: zhaojc01@ustc.edu.cn.
Key points
From the paper's conclusion- These results demonstrate that internal swirl-core redesign improves atomization and mitigates combustion hazards under the tested conditions.
Abstract
Efficient delivery of high-boiling-point fire extinguishing agents requires effective atomization at low operating pressures while limiting hazardous combustion byproducts. Numerical simulations and experiments compared nozzles with identical external dimensions but different internal swirl core geometries. Atomization was evaluated at 0.3-0.6 MPa, with three independent replicates at each pressure. The turbine vane Type C nozzle provided the best combination of flow uniformity and atomization, achieving a mean D0.5 of 210.370 μm at 0.6 MPa. Across the tested pressures, mean D0.5, D0.9, and D0.99 were 268.73, 412.94 and 554.93 μm, respectively, representing reductions of 31.6%, 28.4% and 28.4% relative to Type A. The conventional Rosin-Rammler model poorly represented the coarse tail of measured droplet size distributions. Recalibration using zero-intercept least-squares regression in logarithmic coordinates yielded D0.99/D0.5 = (D0.9/D0.5)1.73, increasing R² from 0.867 to 0.963. In fire-suppression tests at 0.6 MPa, Type C reduced the peak carbon monoxide (CO) concentration by 35.3% compared with Type A, and reduced thermal exposure near the fire. These results demonstrate that internal swirl-core redesign improves atomization and mitigates combustion hazards under the tested conditions. The turbine vane core offers a promising architecture for improved delivery efficiency and hazard control performance of high-boiling-point fire extinguishing agents.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design optimization study on a nozzle for the local application of high-boiling-point extinguishing agentJournal of Physics: Conference Series · 2026
- Optimization of Dust Suppressant Spray Nozzle Design through CFD Simulation and Response Surface MethodologyJournal of Environmental Engineering · 2026
- Quantification of Fine Spray Evolution in Near Field of Various Swirl Burst Injectors Using High-Speed X-Ray ImagingFire · 2026
- Overcoming delivered volume limitations of double-jet impinging atomizers; development of alternative soft mist generation concepts.International journal of pharmaceutics · 2026
- High-Pressure Spray Dynamics of Palm Oil Biodiesel–Diesel Blends: Numerical Simulation and Experimental ValidationFuels · 2026
- Transitioning from Impinging Jets to Single-Jet Impaction: Investigation of an Alternative Nozzle Design for the Respimat® Soft Mist Inhaler.European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences · 2026