Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients in a private practice: A retrospective cohort study.
Rongrong Zhu, Rui Figueiredo, Hongbing Liao, Octavi Camps-Font, Eduard Valmaseda-Castellón, Gang He
Faculty of Medicine and Health Sciences, Universitat de Barcelona, Barcelona, Spain. · Faculty of Medicine and Health Sciences, Universitat de Barcelona, Barcelona, Spain; IDIBELL Institute, Barcelona, Spain. Electronic address: ruipfigueiredo@hotmail.com.
Key points
From the paper's conclusion- d-CAIS demonstrated a high level of accuracy for implant placement in fully edentulous patients, with low mean angular and linear deviations. Increased deviations were associated with older age and with implants placed in the maxilla, anterior region, post-extraction sites, and pterygoid areas.
Abstract
OBJECTIVES: To assess the accuracy of dynamic computer-assisted implant surgery (d-CAIS) in fully edentulous patients in a private practice setting and to identify factors associated with implant placement deviations. METHODS: A retrospective cohort study was conducted including patients treated with d-CAIS between June 2020 and September 2025. Pre- and postoperative cone beam computed tomography (CBCT) scans were superimposed to quantify deviations between planned and actual implant positions. To account for clustering of implants within patients, generalized estimating equation (GEE) models were used. A significance level of p < 0.05 was applied. RESULTS: A total of 107 patients (500 implants) were analyzed. Mean angular deviation was 1.87 ± 1.65°, while mean global deviations at the platform and apex levels were 1.06 ± 0.58 mm and 1.07 ± 0.60 mm, respectively. Mean directional and absolute apical depth deviation was -0.10 ± 0.84 mm and 0.60 ± 0.59 mm. Patient age, jaw (maxilla vs. mandible), implant region (anterior vs. posterior), placement site (healed vs. post-extraction), and pterygoid implants were significantly associated with implant placement deviations. CONCLUSIONS: d-CAIS demonstrated a high level of accuracy for implant placement in fully edentulous patients, with low mean angular and linear deviations. Increased deviations were associated with older age and with implants placed in the maxilla, anterior region, post-extraction sites, and pterygoid areas. CLINICAL SIGNIFICANCE: Dynamic navigation allows reliable implant placement in fully edentulous patients, despite the absence of stable anatomical references. Awareness of factors associated with increased deviations may help optimize treatment planning and improve surgical precision in complex cases.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of Dynamic Computer-Assisted Surgery for Pterygoid Implant Placement in Fully and Partially Edentulous Maxillae: A Retrospective Comparative Study.Medicina (Kaunas, Lithuania) · 2026
- Static, Dynamic and Robotic CAIS in Healed Partially Edentulous Sites: Accuracy and Chair‐Side TimeClinical Implant Dentistry and Related Research · 2026
- Accuracy of Robotic Computer-Assisted Implant Surgery in Fully Edentulous Patients: A Systematic Review and Meta-Analysis.Journal of dentistry · 2026
- Operator experience on robotic and dynamic computer-assisted implant surgery (CAIS): an in vitro controlled study.Journal of dentistry · 2026
- Short implant placement using dynamic and robotic computer-assisted implant surgery (d-CAIS and r-CAIS): a controlled in vitro study.Journal of dentistry · 2026
- Effect of Alveolar Ridge Inclination on Dynamic Navigation Accuracy of Implant Surgery: A Retrospective Clinical Study.Clinical, cosmetic and investigational dentistry · 2026