Journal of dentistry

Evaluation of full-veneer crowns fabricated with 3D printing resin material for definitive prostheses: A 1-year randomized controlled prospective study.

Heedo Shin, Kyung Chul Oh, Jee-Hwan Kim

Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea. · Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea. Electronic address: jee917@yuhs.ac.

Randomised

Key points

From the paper's conclusion
  • Definitive 3D-printed resin crowns showed acceptable marginal adaptation, with no significant differences from zirconia crowns in short-term periodontal outcomes or patient satisfaction. However, their greater occlusal wear and numerically higher fracture incidence may raise concerns regarding mechanical durability as definitive posterior restorations. Longer-term studies are required before broader clinical application.

Abstract

OBJECTIVES: To compare the 1-year clinical performance of definitive 3D-printed resin crowns (RCs) and monolithic zirconia crowns (ZCs) used as tooth-supported posterior single crowns. METHODS: Fifty-six adults requiring tooth-supported posterior single crowns were randomized 1:1 to receive an RC or ZC. Marginal and internal gaps were measured before cementation using the replica technique. Occlusal wear was assessed from intraoral scans obtained at 1 week and 1 year. Crown fractures, periodontal outcomes, and patient satisfaction were also evaluated. Survival distributions were compared with the two-sided log-rank test, and other outcomes were analyzed using Fisher exact or Mann-Whitney U tests. RESULTS: Six RCs and 2 ZCs fractured. One-year fracture-free survival was 78.6% (95% confidence interval [CI], 58.4% to 89.8%) for RCs and 92.9% (95% CI, 74.3% to 98.2%) for ZCs, with no significant difference (P=0.12). Seven of the 8 fractures occurred in the most-posterior restored teeth, and this status was associated with fracture incidence (P=0.002). Marginal and axial gaps did not differ significantly, whereas axio-occlusal and occlusal gaps were smaller for RCs (P<0.05). RCs showed greater wear depth (92.33 ± 69.81 versus 14.48 ± 7.95 μm) and wear volume (4.31 ± 3.68 versus 0.47 ± 0.31 mm³) than ZCs (P<0.05). Periodontal outcomes and patient satisfaction did not differ significantly. CONCLUSIONS: Definitive 3D-printed resin crowns showed acceptable marginal adaptation, with no significant differences from zirconia crowns in short-term periodontal outcomes or patient satisfaction. However, their greater occlusal wear and numerically higher fracture incidence may raise concerns regarding mechanical durability as definitive posterior restorations. Longer-term studies are required before broader clinical application. CLINICAL SIGNIFICANCE: The definitive 3D-printed resin crowns showed acceptable marginal adaptation but greater measured occlusal wear and a numerically higher fracture incidence than monolithic zirconia crowns over 1 year. These findings warrant caution when using these restorations as definitive posterior single crowns, with continued monitoring of wear and restoration integrity.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers