An LC-MS/MS assay for quantification of plasma biomarkers to assess transporter-mediated drug-drug interactions and biomarker baselines in healthy volunteers.
Nikoleta Palioudaki, Rune Aabjerg Nørgaard, Stine Krogh Steffensen, Lise Lotte Gluud, Tue Bjørn Søeborg, Nikoline Juul Nielsen
Non-Clinical & Clinical Assay Sciences, Global Discovery & Development Sciences, Novo Nordisk A/S, DK-2760 Måløv, Denmark; Analytical Chemistry Group, Department of Plant and Environmental Sciences, University of Copenhagen, Thorvaldsensvej 40, DK-1871 Frederiksberg C, Denmark. · Development ADME, Global Discovery & Development Sciences, Novo Nordisk A/S, DK-2760 Måløv, Denmark.
Key points
From the paper's conclusion- The final method was applied to plasma samples from healthy volunteers, resulting in a geomean of the baseline levels of 0.52 ng/mL for CPI, 5.5 ng/mL for PDA, 14.7 ng/mL for NMN, and 28.9 ng/mL for m1A, consistent with previously published data.
Abstract
Endogenous molecules are proposed as biomarkers to assess drug transporter function, with changes in their concentrations reflecting altered transporter activity. In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed, comprising a hydrophilic interaction liquid chromatography (HILIC) method and a reversed-phase liquid chromatography (RPLC) method both with MS/MS, using a single supernatant to quantify plasma biomarkers of clinically relevant drug transporters: coproporphyrin I (CPI), 4-pyridoxic acid (PDA), N1-methylnicotinamide (NMN), and 1-methyladenosine (m1A). Optimization resulted in a 5-min HILIC method for PDA, NMN, and m1A using a pH 9 mobile phase containing 10 mM ammonium acetate and 0.04% ammonium hydroxide to achieve acceptable peak shapes and retention, with 5% methanol added to the organic phase to maintain salt solubility. For CPI and CPIII, a 3.5-min RPLC method at pH 2.7 enabled baseline separation of the two isomers with a low gradient steepness of 0.032 at 60 °C. Protein precipitation provided lower limits of quantification of 0.18-4.00 ng/mL across the different biomarkers, while parallelism experiments confirmed 3 × charcoal-stripped K2EDTA human plasma as a suitable surrogate matrix. Fit-for-purpose validation demonstrated intra- and inter-assay accuracy and precision and confirmed assay selectivity. The final method was applied to plasma samples from healthy volunteers, resulting in a geomean of the baseline levels of 0.52 ng/mL for CPI, 5.5 ng/mL for PDA, 14.7 ng/mL for NMN, and 28.9 ng/mL for m1A, consistent with previously published data. The variation in the baseline levels was mainly described by sex for CPI and by the sex-age interaction for PDA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Endogenous Biomarkers to Evaluate Transporter-Mediated Drug-Drug Interactions: Current Evidence, Impact on Clinical Pharmacology Strategy, Remaining Gaps, and Future Directions.Journal of clinical pharmacology · 2026
- Discovery of novel plasma biomarkers for OATP1B1 activity using nontargeted metabolomics.Drug metabolism and disposition: the biological fate of chemicals · 2026
- A generalizable fit-for-purpose workflow for multiplex targeted mass-spectrometry of protein-based blood biomarkers: validation and clinical application to neurodegenerative diseases in a 400-patient cohort.Clinical chemistry and laboratory medicine · 2026
- B-342 Long run LC–MS/MS robustness in human plasma: a 30,000-injection evaluation of quantitative stability, carryover, and uptime on a triple quadrupole platform for clinical researchClinical Chemistry · 2026
- Biomarker‐Based Prediction of OATP1B1 Activity in Clinical Routine—Investigating Coproporphyrins as Markers for Drug–Drug–Gene InteractionsClinical Pharmacology & Therapeutics · 2026
- LC-MS/MS quantification of trimethylamine N-oxide in plasma and volumetric absorptive microsamples: analytical validation and feasibility in pediatric kidney transplant recipients.Clinica chimica acta; international journal of clinical chemistry · 2026