Can artificial intelligence add diagnostic value for human readers in detecting coronary artery stenosis on coronary CT angiography? A Bayesian network meta-analysis.
Yuxi Jiang, Zhichun Liu, Tianrun Yang, Junwei Shi, Jiamei Fu
Heilongjiang University of Chinese Medicine, Harbin 150040, Heilongjiang, China. · Graduate School, Heilongjiang University of Chinese Medicine, Harbin 150040, Heilongjiang, China.
Key points
From the paper's conclusion- Stand-alone DL and AI-assisted reading had similar estimated diagnostic performance. AI assistance improved sensitivity most clearly for less-experienced readers. These accuracy comparisons did not establish formal equivalence or determine whether stand-alone DL could replace human interpretation in clinical practice.
Abstract
AIMS: The incremental diagnostic value of artificial intelligence (AI) in coronary CT angiography (CCTA) remains uncertain. We compared five CCTA strategies: automated stenosis assessment software (COR Analyzer), stand-alone CCTA-based deep learning (DL), junior readers, senior readers, and AI-assisted readers, for detecting anatomical coronary artery stenosis against invasive coronary angiography. METHODS AND RESULTS: PubMed, Embase, Web of Science, and the Cochrane Library were searched from inception through July 9, 2026. Twenty-two observational diagnostic accuracy studies were included (19 retrospective and three prospective; 21 for ≥50% stenosis and six for ≥70% stenosis). In the primary patient-level analysis at ≥50% stenosis, pooled sensitivity for DL and AI-assisted readers was 0.91 each (95% credible interval, 0.87 to 0.94 and 0.86 to 0.94), versus 0.80 (0.73-0.87) for junior and 0.87 (0.82-0.91) for senior readers; AI assistance increased sensitivity by 0.10 versus junior readers (0.06-0.15) and 0.03 versus senior readers (0.01-0.06). Specificity was similar across DL and reader strategies (0.64-0.67) but markedly lower for COR Analyzer (0.25 [0.15 to 0.38]). In the smaller ≥70% network, AI-assisted reading showed the highest estimated sensitivity (0.80 [0.70 to 0.88]). Findings were robust to outlier exclusion; certainty was low to very low for most ≥50% outcomes. CONCLUSION: Stand-alone DL and AI-assisted reading had similar estimated diagnostic performance. AI assistance improved sensitivity most clearly for less-experienced readers. These accuracy comparisons did not establish formal equivalence or determine whether stand-alone DL could replace human interpretation in clinical practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of artificial intelligence-based coronary artery analysis in the emergency department: A multicenter study.Journal of cardiovascular computed tomography · 2026
- Performance of artificial intelligence-based coronary CT angiography-derived fractional flow reserve across cohorts with different prevalence of obstructive coronary artery disease.Journal of cardiovascular computed tomography · 2026
- High-Strength Deep Learning Image Reconstruction Versus Adaptive Statistical Iterative Reconstruction for Stenosis Assessment in Stented Coronary Vessels on Coronary CT Angiography: A Multireader Study.Journal of clinical medicine · 2026
- A deep learning-based algorithm for detecting significant in-stent restenosis in coronary CT angiography.The international journal of cardiovascular imaging · 2026
- Comparative validation and clinical utility of an artificial intelligence-based CT-SYNTAX score in complex coronary artery disease.The international journal of cardiovascular imaging · 2026
- Diagnostic Performance of Angiography-Derived MPFFR for Predicting Hemodynamically Significant Coronary Stenosis: A Multicenter Validation Study.Diagnostics (Basel, Switzerland) · 2026