A deep learning-based algorithm for detecting significant in-stent restenosis in coronary CT angiography.
Daebeom Park, Yoon Seong Lee, Baren Jeong, Ji Young Song, Eun-Ah Park, Whal Lee
Department of Clinical Medical Sciences, Seoul National University College of Medicine, Seoul, Korea. · Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Korea.
Key points
From the paper's conclusion- This study developed and evaluated a deep learning algorithm for automated detection of significant ISR in CCTA images.
Abstract
Coronary CT angiography (CCTA) is widely used for monitoring patients after stent implantation, but beam-hardening and blooming artifacts make assessment of in-stent restenosis (ISR) challenging. This study developed and evaluated a deep learning algorithm for automated detection of significant ISR in CCTA images. A retrospective analysis of 257 patients with 408 stents was conducted, divided into a development set (n = 126 patients, 186 stents) and an internal validation set (n = 131 patients, 222 stents), with invasive coronary angiography serving as the reference standard. The algorithm's diagnostic performance was compared to two expert radiologists using standard diagnostic metrics. The deep learning algorithm achieved 87.8% accuracy (95% confidence interval [CI], 82.9-91.5%), with sensitivity of 75.4% (95% CI, 62.9-84.8%), specificity of 92.1% (95% CI, 87.0-95.3%), positive predictive value (PPV) of 76.8% (95% CI, 64.2-85.9%), and negative predictive value (NPV) of 91.6% (95% CI, 86.3-94.9%). McNemar's test revealed no significant differences in overall diagnostic accuracy between the algorithm and Reader1 (p = 0.133) or Reader2 (p = 0.150). Notably, the algorithm demonstrated significantly higher sensitivity compared to both readers (43.9% [95% CI, 31.8-56.7%] and 56.1% [955% CI, 43.3-68.2%], p < 0.05) and higher NPV compared to Reader1 (p = 0.026). Subgroup analyses confirmed higher sensitivity across different scanner platforms and imaging conditions, including GE systems (p = 0.016) and 80 kilovoltage peak settings (p = 0.006). The deep learning algorithm demonstrated higher sensitivity for detecting significant ISR while maintaining comparable overall diagnostic accuracy to expert radiologists, although this was accompanied by numerically slightly lower specificity, supporting its potential as a decision-support tool.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- High-Strength Deep Learning Image Reconstruction Versus Adaptive Statistical Iterative Reconstruction for Stenosis Assessment in Stented Coronary Vessels on Coronary CT Angiography: A Multireader Study.Journal of clinical medicine · 2026
- Deep Learning Optimizes the Diagnostic Performance of Coronary Computed Tomography Angiography in Heavily Calcified Coronary Plaques: A Chinese Multicenter Study.Reviews in cardiovascular medicine · 2026
- Diagnostic accuracy of photon-counting detector CT for detection of coronary in-stent restenosis.Cardiovascular revascularization medicine : including molecular interventions · 2026
- Deep learning-based assessment of coronary artery disease using curved-multiplanar reconstruction: comprehensive evaluation of stenosis, calcification, and plaqueEuropean Heart Journal · 2026
- Can artificial intelligence add diagnostic value for human readers in detecting coronary artery stenosis on coronary CT angiography? A Bayesian network meta-analysis.Journal of cardiovascular computed tomography · 2026
- Assessing coronary in-stent restenosis using ultrahigh-resolution photon-counting detector CT: results from a two-center studyEuropean Journal of Radiology · 2026