Native varus angle does not affect the primary fixation of cementless TKA using kinematic alignment - A population-based FE study.
Verena Helgers, Periklis Tzanetis, Thom Bitter, Adam Briscoe, Hans-Peter van Jonbergen, Ellie Landman, Nico Verdonschot, Dennis Janssen
Orthopaedic Research Laboratory, Radboud University Medical Center, Nijmegen, the Netherlands. Electronic address: verena.helgers@radboudumc.nl. · Laboratory for Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, the Netherlands.
Key points
From the paper's conclusion- Overall, PEEK models generated larger micromotions than CoCr models.
Abstract
Proper primary fixation in cementless total knee arthroplasty (TKA) is essential for long-term survival of the implant. It is, however, poorly understood how different surgical implant alignment techniques and implant materials impact implant fixation. The aim of this computational study was therefore to investigate the effect of variations in coronal knee alignment on the primary fixation of femoral cementless polyetheretherketone (PEEK-OPTIMA™) and Cobalt-Chromium (CoCr) TKA in a patient population. Patient-specific finite element (FE) models of kinematically aligned femoral reconstructions of 179 varus patients (0-9 degrees) were created, varying the implant material (CoCr and PEEK) and applying patient-scaled loading conditions determined from musculoskeletal models. These variations resulted in 716 FE simulations. The primary fixation of the implant was quantified by the median and maximum values of the resulting micromotions on the bone-implant surface. Micromotions remained stable across different varus angles for both PEEK and CoCr models. Overall, PEEK models generated larger micromotions than CoCr models. However, both CoCr (3.6 µm) and PEEK (19.1 µm) displayed median micromotions below the threshold range of 40 to 112 µm for osseointegration. This study presents the results of a novel workflow investigating the effect of implant material and kinematic alignment on primary fixation of cementless TKA reconstructions in Dutch varus patients. The current results do not suggest an effect of varus alignment on primary fixation and micromotion distribution. Future studies will compare these outcomes with mechanical alignment applied to the same cohort, this may present more pronounced differences in fixation at larger native varus angles.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Kinematic Alignment in TKA Using the Contralateral Healthy Knee as Reference: A Combined Finite Element and Clinical Analysis.Orthopaedic surgery · 2026
- Navigation-Assisted and Robotic Total Hip, Knee, and Unicompartmental Arthroplasty: Reconciling Positioning Accuracy with Biomaterial Performance and Long-Term Implant Survival.Bioengineering (Basel, Switzerland) · 2026
- Asymmetric metaphyseal cones versus medial modular block augment with central cone for medial tibial defects : a biomechanical comparison in varying bone quality.Bone & joint research · 2026
- Tibiofemoral and patellofemoral kinematics after kinematic versus mechanical alignment in varus TKA-a dynamic knee rig study.Archives of orthopaedic and trauma surgery · 2026
- A Simplified Model of the Knee for Coronal Plane Alignment of the Knee Simulation.Bioengineering (Basel, Switzerland) · 2026
- Unrestricted kinematic alignment in varus total knee arthroplasty outperforms mechanical alignment in CPAK I phenotype, but yields comparable outcomes in CPAK IV: A retrospective analysis from the FP‐UCBM Knee Study GroupKnee Surgery Sports Traumatology Arthroscopy · 2025