Transcatheter Mitral Valve Replacement in an Incomplete Ring With LAMPOON Facilitated By Aortic Prosthesis.
Denizhan Ozdemir, Mandeep Singh, Jeffrey Bruckel, Farhan Bajwa, Kazuhiro Hisamoto, Elizabeth Melito, Frederick Ling
Division of Cardiology, University of Rochester Medical Center, Rochester, New York, USA. Electronic address: Denizhan_Ozdemir@URMC.Rochester.edu. · Division of Cardiology, University of Rochester Medical Center, Rochester, New York, USA.
Key points
From the paper's conclusion- A 54-year-old man with ischemic cardiomyopathy, prior coronary artery bypass grafting, aortic valve-in-valve transcatheter aortic valve replacement, mitral repair with a 31-mm Duran AnCore band, and tricuspid annuloplasty presented with NYHA functional class IV heart failure from severe recurrent mitral regurgitation.
Abstract
BACKGROUND: Transcatheter mitral valve replacement in large incomplete flexible mitral bands is high risk because limited anchoring and anterior leaflet displacement may cause embolization or left ventricular outflow tract (LVOT) obstruction. CASE SUMMARY: A 54-year-old man with ischemic cardiomyopathy, prior coronary artery bypass grafting, aortic valve-in-valve transcatheter aortic valve replacement, mitral repair with a 31-mm Duran AnCore band, and tricuspid annuloplasty presented with NYHA functional class IV heart failure from severe recurrent mitral regurgitation. Computed tomography excluded SAPIEN M3 (predicted neo-LVOT 0 mm2) and showed a long anterior mitral leaflet, raising concern for dynamic obstruction despite a predicted neo-LVOT of 347.6 mm2 for a 29-mm balloon-expandable valve. He underwent antegrade base-to-tip laceration of the anterior mitral leaflet to prevent outflow obstruction, followed by valve-in-ring transcatheter mitral valve replacement, with no paravalvular leak or significant LVOT gradient. DISCUSSION: Anterior aortic prosthetic anatomy facilitated valve anchoring despite the incomplete flexible band, which would have been prohibitive in the absence of anterior bioprosthesis. TAKE-HOME MESSAGE: Adjacent prosthetic anatomy may be leveraged in selected complex valve-in-ring procedures after meticulous multimodality planning and procedural expertise.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prevention of Left Ventricular Outflow Tract Obstruction During High-Risk Transcatheter Mitral Valve Replacement.JACC. Case reports · 2026
- Anterior mitral leaflet modification to prevent left ventricular outflow tract obstruction during transcatheter mitral valve replacement: the PROTECT-LVOT registry.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2026
- Transcatheter Valve-in-Band Implantation in a Swine Model of Failed Mitral Repair: A Technical Note and Proof of Feasibility.Journal of clinical medicine · 2026
- Retrograde Mitral Paravalvular Leak Closure Through a Mechanical Aortic Prosthesis After Failed Antegrade Access.JACC. Case reports · 2026
- Valve-in-valve transcatheter mitral valve replacement via totally endoscopic endoclamp-assisted approach after failed bioprosthetic mitral valve: a case report.Journal of cardiothoracic surgery · 2026
- Left ventricular outflow tract obstruction in transcatheter mitral interventions: percutaneous anterior leaflet modification.European heart journal · 2026