Transseptal Transcatheter Mitral Valve Replacement Under Deep Sedation With Spontaneous Ventilation.
André Lobo, Ana Fonte Boa, Luís Puga, Bruno Melica
Department of Cardiology, Unidade Local de Saúde de Gaia e Espinho, Vila Nova de Gaia, Portugal. Electronic address: andresmplobo@gmail.com. · Department of Anaesthesiology, Unidade Local de Saúde de Gaia e Espinho, Vila Nova de Gaia, Portugal.
Key points
From the paper's conclusion- This case demonstrates that SAPIEN M3 implantation is feasible under deep sedation with spontaneous ventilation.
Abstract
OBJECTIVE: The SAPIEN M3 is a transseptal system for transcatheter mitral valve replacement, and published experience of implantation has been under general anesthesia. We describe its implantation under deep sedation with spontaneous ventilation, without tracheal intubation. KEY STEPS: Confirm adequate midesophageal and transgastric image quality and favorable computed tomographic anatomy. Place the patient under deep sedation with dexmedetomidine, propofol, and fentanyl, under arterial pressure, bispectral index, and capnographic monitoring, with predefined conversion criteria. Obtain transseptal access, position the dock under prolonged transgastric imaging, and deploy the valve under rapid pacing. Monitor ventilation and oxygenation with serial arterial blood gases. POTENTIAL PITFALLS: Aspiration with an unprotected airway during prolonged probe manipulation, and loss of the stable conditions needed throughout a long procedure, require meticulous anesthetic monitoring and immediate capability for conversion. TAKE-HOME MESSAGES: This case demonstrates that SAPIEN M3 implantation is feasible under deep sedation with spontaneous ventilation. In selected patients at increased risk from general anesthesia, deep sedation may extend this therapy, a possibility that larger series should now test.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Double Transeptal Puncture for SAPIEN M3 Transcatheter Mitral Valve Replacement: Initial Experience, Indications, and Technique.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Deep Sedation in Single-Shot Pulmonary Vein Isolation: A Head-to-Head Look at Two Pulsed Field Versus Cryoballoon Ablation Approaches.Journal of cardiovascular electrophysiology · 2026
- Supra-Inguinal Fascia Iliaca Block Versus Iliohypogastric-Ilioinguinal Block During Transcatheter Aortic Valve Implantation (TAVI) Under Conscious Sedation: A Patient- and Outcome Assessor-Blinded Randomized Trial.Anesthesiology research and practice · 2026
- Low-Volume Superior Trunk and Superficial Cervical Plexus Block With Sedation as the Sole Regional Anesthetic for Proximal Humerus Fracture Fixation in a Patient With Alzheimer Disease.The American journal of case reports · 2026
- Feasibility, Technical Safety, and Early Clinical Experience with an Automated Annular Suturing Device in Minimally Invasive Valve Replacement.Journal of clinical medicine · 2026
- Remimazolam Versus Dexmedetomidine for Monitored Anesthesia Care in Patients Undergoing Transfemoral Transcatheter Aortic Valve Implantation: A Randomized Clinical Trial.Journal of clinical medicine · 2026