Deep Sedation in Single-Shot Pulmonary Vein Isolation: A Head-to-Head Look at Two Pulsed Field Versus Cryoballoon Ablation Approaches.
Joseph A Kheir, David Schaack, Andrea Urbani, Lukas Urbanek, Alexandra Marx, Julia Lurz, Matteo Rocchetti, Paolo D'Andria,
CCB, MVZ CCB Frankfurt und Main Taunus GbR, Markus Hospital, Frankfurt am Main, Germany.
Key points
From the paper's conclusion- The novel BC demonstrated excellent feasibility under DS, with reduced normalized sedative requirements compared with the PC and a safety profile comparable to CB ablation. These findings suggest that optimized waveform design and field homogeneity may enable safe and comfortable PVI under DS without the need for general anesthesia.
Abstract
BACKGROUND: Deep sedation (DS) is routinely used during single-shot pulmonary vein isolation (PVI) to optimize patient comfort and procedural stability. However, data on sedative requirements and procedural tolerance of pulsed field ablation (PFA) under DS compared with thermal technologies remain limited. METHODS: In this single-center study, consecutive patients underwent PVI with cryoballoon (CB), PFA using a pentaspline catheter (PC) or the balloon-in-basket catheter (BC). All procedures were performed under DS with midazolam, fentanyl, and propofol, administered by electrophysiology staff without anaesthesiologist supervision. Propensity score matching (1:1:1) was applied for age, sex, body mass index, and hypertension. Procedural characteristics, sedative/analgesic requirements, and complications were analyzed. RESULTS: Acute PVI without major complications was achieved in all 156 enrolled patients. PC procedures were associated with higher body-weight- and time-adjusted requirements for propofol (CB: 0.10 ± 0.04 mg/kg/min; PC: 0.15 ± 0.04 mg/kg/min; BC: 0.11 ± 0.03 mg/kg/min; p < 0.001) despite the lowest total dose of propofol used (CB: 440 ± 144 mg; PC: 348± 80 mg; BC: 433 ± 160 mg; p = 0.00). Procedural times (CB: 47.5 [40-60] min, PC: 29 [25-35] min, BC: 47.5 [40-56] min, p < 0.001) and fluoroscopy times (CB: 9.5 [6.3-13.6] min; PC: 6.2 [4.4-9] min; BC: 7.2 [6.1-11.2] min, p = 0.001) were shortest in the PC group. Sedation-related hemodynamic stability was comparable across all cohorts. CONCLUSIONS: The novel BC demonstrated excellent feasibility under DS, with reduced normalized sedative requirements compared with the PC and a safety profile comparable to CB ablation. These findings suggest that optimized waveform design and field homogeneity may enable safe and comfortable PVI under DS without the need for general anesthesia.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- “Awake and Ablated”: First experience with a balloon-in-basket PFA system without propofolHeart Rhythm O2 · 2025
- Outcomes and patient satisfaction of deep sedation versus general anesthesia during dual-energy catheter ablation for paroxysmal atrial fibrillation: a randomized clinical trialEuropean Heart Journal · 2026
- Sedation and anaesthesia in pulsed-field ablation for atrial fibrillation: mechanisms, procedural requirements, and real-world practice.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- A Comparison of Safety and Outcome Using Three Different Sedation Strategies During Pulsed Field Ablation for Atrial Fibrillation.Journal of cardiovascular electrophysiology · 2026
- The Effectiveness and Safety of Deep Sedation Protocols for Pulsed Field Ablation of Atrial Fibrillation.Pacing and clinical electrophysiology : PACE · 2026
- Sedation strategies for pulsed field ablation: a FARADISE registry sub-analysisEuropean Heart Journal · 2026