Passivity-based fault-tolerant control of onboard skew-symmetric DC microgrids for more electric aircraft: A plug-and-play scheme.
Haocheng An, Jian-Ning Li, Xuelin Zhang, Aimin Wang
School of Automation, Hangzhou Dianzi University, Hangzhou 310018, China. Electronic address: 252060149@hdu.edu.cn. · School of Automation, Hangzhou Dianzi University, Hangzhou 310018, China. Electronic address: ljn@hdu.edu.cn.
Key points
From the paper's conclusion- Onboard DC microgrids (DCMGs) are becoming the electrical backbone of more electric aircraft (MEA), where actuator faults and plug-and-play (PnP) reconfiguration may occur within the same mission segment.
Abstract
Onboard DC microgrids (DCMGs) are becoming the electrical backbone of more electric aircraft (MEA), where actuator faults and plug-and-play (PnP) reconfiguration may occur within the same mission segment. To address these issues, this paper develops a passivity-based PnP fault-tolerant control (FTC) scheme for MEA DCMGs. An interconnected DCMG model is formulated with distributed generators (DGs) subject to actuator faults and dynamic π-equivalent transmission lines. Equilibrium shifting and a structured storage function establish local passivity of the faulty DGs and yield explicit local proportional-integral (PI) gain inequalities over certified actuator-effectiveness bounds. A positive margin in the inductance condition is also quantified for fixed parameter realizations within certified bounds. A skew-symmetric DG-line port representation and an invariant-set argument establish asymptotic stability of the shifted network for each fixed admissible configuration. The gain inequalities permit local PnP admission without solving a new linear matrix inequality (LMI) feasibility problem or retuning previously admitted DG controllers, provided the resulting operating point is feasible. Simulations conducted with the Specialized Power Systems Toolbox in MATLAB/Simulink show that, following the tested PnP and fault events, DG bus voltages recover within 0.669 s and their steady-state errors remain below 0.05 V.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Decentralized plug-and-play control of grid-forming converters for resilient and scalable AC microgrids: a passivity-based unified architectureScientific Reports · 2026
- Resilient Distributed Observer-Based Fault-Tolerant Control for Islanded AC Microgrids Subject to Actuator Fault and Saturation ConstraintsIEEE Transactions on Consumer Electronics · 2026
- Predefined‐Time Distributed Adaptive Fault‐Tolerant Voltage Regulation for AC Microgrids With Unknown Actuator FaultsInternational Journal of Adaptive Control and Signal Processing · 2026
- Group Consensus-Based Secondary Control for Islanded AC Microgrids With Communication Link and Actuator Faults.IEEE transactions on cybernetics · 2026
- Event-triggered adaptive fixed-time sliding mode control for voltage regulation of spacecraft DC microgridsEngineering Research Express · 2026
- Robust-powered yaw control of aircraft with distributed electric propulsorsThe Aeronautical Journal · 2026