Decentralized plug-and-play control of grid-forming converters for resilient and scalable AC microgrids: a passivity-based unified architecture
Abhay Chaturvedi, Dinesh Kumar Nishad, Kamlesh Kumar Bharti, Raghvendra Tiwari, Molla Addisu Mossie
Key points
From the paper's conclusion- We present a generic decentralized plug-and-play (PnP) design for all grid-forming (GFM) converters by including the same kernel, i.e., droop primary regulation, adaptive virtual impedance, sparse consensus-based secondary restoration, and trust-weighted resilient coordination, under a local passivity-based admission test.
Abstract
In low-inertia AC microgrids, voltage formation, frequency support, power sharing, and disturbance rejection are performed by grid-forming (GFM) converters. Current systems often design these functions individually for a fixed, cooperatively tuned converter population. Adding, removing, or losing a unit requires retuning, which may jeopardize stability. We present a generic decentralized plug-and-play (PnP) design for all grid-forming (GFM) converters by including the same kernel, i.e., droop primary regulation, adaptive virtual impedance, sparse consensus-based secondary restoration, and trust-weighted resilient coordination, under a local passivity-based admission test. Under explicitly stated assumptions (quasi-stationary lossy lines, a feasible equilibrium, a connected electrical network and a bounded admission rate), we prove that a converter with normalized passivity index exceeding a strictly positive margin can be admitted or removed without neighbor retuning, that stability is preserved during the finite-time admission ramp and not only at its end points, and that the conductive (R/X) coupling of real feeders enters the test as a bounded, locally computable defect. The same certificate bounds the perturbation that false-data-injection (FDI) attacks can cause through the trust-weighted consensus, with an explicit relation between attack magnitude, residual threshold, trust weight, and perturbation. Validation is software-only: a detailed averaged three-converter Simulink model, a small-signal model with the exact lossy Jacobian for $$\:N\:=\:2-128$$ converters, several electrical and communication graphs, heterogeneous ratings and lines, sequential and simultaneous multi-unit events, a documented Monte-Carlo campaign and a 15-scenario FDI campaign. In the detailed model, admitting a converter causes a peak PCC voltage deviation of 1.79% (settling in 58 ms), and the harmonic kernel (current feed-forward plus selective resonant feedback of the PCC voltage) lowers PCC voltage THD from 9.19% to 3.33%, within the 5% limit. The computed minimum passivity index during admission is 0.723 over $$\:N\:=\:2-8$$ and remains between 0.723 and 0.885 up to $$\:N\:=\:128$$ ; the Monte-Carlo violation probability is 0.002 for design tolerances ( $$\:M\:=\:1000$$ ). Real-time hardware-in-the-loop testing was not performed and is identified as future work.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Passivity-based fault-tolerant control of onboard skew-symmetric DC microgrids for more electric aircraft: A plug-and-play scheme.ISA transactions · 2026
- Distributed Optimal Control of AC Microgrids with Coupled Voltage and Frequency RegulationEnergies · 2026
- Scalable Adaptive Fuzzy Voltage Control for DC Microgrids With Plug-and-Play Operations and Constant Power Loads.IEEE transactions on cybernetics · 2026
- Passivity-Based Decentralized Stability Criterion and Active-Damping Design for DC MicrogridsarXiv · 2026
- Predefined‐Time Distributed Adaptive Fault‐Tolerant Voltage Regulation for AC Microgrids With Unknown Actuator FaultsInternational Journal of Adaptive Control and Signal Processing · 2026
- Passivity Shaping over Frequency Bands: A Differentiable Optimization ApproacharXiv · 2026