Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in Patients with Bicuspid Aortic Valves: A Systematic Review and Meta-Analysis.

Dr Sundar Chidambaram, Dr P Manokar, Dr Jebaraj, Dr Maheshbabu P, Dr Mahadevan V, Dr Deepchand Raja, Dr Nitheshkumar, Dr Surendhar G,

Kauvery Hospital, Vadapalani, Chennai, India. Electronic address: sundarsaivimal@gmail.com. · Kauvery Hospital, Vadapalani, Chennai, India.

Meta-analysis

Key points

From the paper's conclusion
  • Available head-to-head evidence does not demonstrate a clear difference in early device success between contemporary BEV and SEV in BAV, but the evidence is sparse, predominantly observational and imprecise. The findings should not be interpreted as proof of equivalence. Prospective comparative studies with standardized BAV phenotyping are required.

Abstract

BACKGROUND/OBJECTIVES: The comparative performance of balloon-expandable (BEV) and self-expanding (SEV) transcatheter heart valves in bicuspid aortic valve (BAV) stenosis remains uncertain. METHODS: We systematically reviewed contemporary BAV-TAVR literature published from 2015 to 2025. The broader qualitative evidence map comprised 69 reports, including device-specific and comparative cohorts; however, only studies with extractable arm-level BEV-versus-SEV data were eligible for quantitative comparative pooling. RESULTS: Three head-to-head cohorts contributed to early/30-day device success (BEV 302/353; SEV 160/181). The pooled RR for SEV versus BEV was 1.03 (95% CI 0.96-1.09; I2=0%). Two cohorts contributed to 30-day permanent pacemaker implantation (PPI), showing a numerically higher but non-significant risk with SEV (RR 2.01; 95% CI 0.93-4.37; I2=0%). Only one study provided compatible 30-day arm-level data for moderate-or-greater paravalvular leak (PVL), precluding pooling. Adjusted and single-arm observational evidence suggested possible platform-specific differences in hemodynamics, PVL and conduction outcomes, but these data were not interpreted as evidence of comparative equivalence or superiority. CONCLUSIONS: Available head-to-head evidence does not demonstrate a clear difference in early device success between contemporary BEV and SEV in BAV, but the evidence is sparse, predominantly observational and imprecise. The findings should not be interpreted as proof of equivalence. Prospective comparative studies with standardized BAV phenotyping are required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers