Long-term outcomes after balloon- or self-expandable transcatheter aortic valve replacement in small aortic annuli.
Toshinobu Ryuzaki, Kentaro Hayashida, Kei Kamata, Ryo Arita, Tomonari Moriizumi, Juri Iwata, Taku Hiramatsu, Akito Matsumura,
Department of Cardiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan. · Department of Cardiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan. khayashidamd@gmail.com.
Key points
From the paper's conclusion- These findings underscore the need for further investigations using larger cohorts and contemporary devices to validate long-term comparative outcomes of BEV and SEV in patients with SAA.
Abstract
Transcatheter aortic valve replacement (TAVR) is an established treatment for severe aortic stenosis. In patients with small aortic annuli (SAA), self-expandable valves (SEV) provide better hemodynamic performance than balloon-expandable valves (BEV); however, long-term outcomes remain unclear. We retrospectively analyzed 564 consecutive patients with SAA who underwent TAVR with follow-up of > 5 years, comparing BEV (n = 476) and SEV (n = 88). After propensity score (PS) matching, 84 patients were included in each group. Clinical outcomes were evaluated over a median follow-up of 2,134 days. Sensitivity analyses using inverse probability of treatment weighting were also performed. SEV was more frequently selected in patients with more severe baseline AS. SEV demonstrated more favorable post-procedural hemodynamics; BEV was associated with lower paravalvular leakage, whereas the difference in permanent pacemaker implantation was attenuated after PS matching. In the overall and propensity score-matched cohorts, there were no significant differences between BEV and SEV with respect to all-cause death, cardiovascular death, or first heart failure hospitalization. Moderate or greater hemodynamic valve deterioration incidence did not differ between groups in the overall (log-rank test, p = 0.372) or PS-matched cohort (log-rank test, p = 0.182). BVF events were rare in the overall cohort, and no BVF events occurred in the PS-matched cohort. SEV was associated with superior postprocedural hemodynamics; however, no significant differences in long-term clinical outcomes were observed compared with BEV. These findings underscore the need for further investigations using larger cohorts and contemporary devices to validate long-term comparative outcomes of BEV and SEV in patients with SAA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Self-expanding vs. balloon-expandable valves in small annulus patients undergoing transcatheter aortic valve implantationEuropean Heart Journal · 2026
- Outcomes of Supra-Annular vs Intra-Annular Self-Expanding Valves in Valve-In-Valve Transcatheter Aortic Valve Replacement.JACC. Cardiovascular interventions · 2026
- Newer-generation balloon-expandable vs. self-expanding transcatheter aortic valves: a propensity score matched analysis.Journal of cardiovascular medicine (Hagerstown, Md.) · 2026
- Long-term outcomes and durability of balloon-expandable TAVI in small and large annuliEuroIntervention · 2025
- Comparative Outcomes of Self-Expanding Versus Balloon-Expandable Valves in Severe Aortic Stenosis: A Systematic Review and Meta-Analysis.Cardiology in review · 2026