Comparative Clinical and Procedural Outcomes Among Three Pulsed Field Ablation Systems for Atrial Fibrillation: A Prospective Real-World Study.
Verena Tscholl, Toshinori Chiba, Reza Wakili, Laura Rottner, David M Leistner, Esther Roth, Claudius Sebastian Baldauf, Cerine Benachi,
Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Campus Mitte, Berlin, Germany. · Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, Campus Mitte, Berlin, Germany. Electronic address: toshinori.chiba@dhzc-charite.de.
Key points
From the paper's conclusion- In this prospective real-world study, PVI with the CMAC, VLCC, and LTC showed comparable efficacy and safety outcomes, while procedural profiles differed.
Abstract
BACKGROUND: Pulsed Field Ablation (PFA) is a non-thermal ablation technology for atrial fibrillation. Several PFA systems are available, with distinct catheter designs and energy delivery protocols. Direct comparisons between PFA systems remain limited. OBJECTIVE: This study compared the procedural characteristics, safety, and efficacy of three contemporary PFA technologies in routine clinical practice. METHODS: Consecutive patients undergoing their first pulmonary vein isolation (PVI) using the circular multielectrode array catheter (CMAC)(PulseSelectTM), the variable-loop circular catheter (VLCC)(VaripulseTM) or the lattice-tip catheter (LTC)(AfferaTM) were prospectively included. Freedom from any atrial arrhythmia (AA) was evaluated using 12-lead electrocardiography and 24-hour Holter at 3, 6 and 12 months, followed by routine clinical follow-up. RESULTS: A total of 198 patients (CMAC:91, VLCC:50, LTC: 57) were included. Acute PVI was achieved in all patients (median age, 68 [61.0, 76.0] years; 127 male (64.1%); 97 paroxysmal (49.0%)). The procedure and ablation times were longest in the LTC group. During a mean follow-up of 352.4±207.2 days, the estimated 12-month freedom from AA recurrence beyond the 8-week blanking period was comparable among the CMAC, VLCC, and LTC groups (76.9%, 71.6%, and 78.8%; log-rank p=0.72). In adjusted multivariable Cox regression, PFA system choice was not associated with AA recurrence (LTC vs. CMAC: HR 0.77, 95% CI 0.39-1.52, p=0.45; VLCC vs. CMAC: HR 1.16, 95% CI 0.58-2.34, p=0.67). One major complication (0.51%, ischemic stroke (CMAC)) occurred. CONCLUSION: In this prospective real-world study, PVI with the CMAC, VLCC, and LTC showed comparable efficacy and safety outcomes, while procedural profiles differed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Procedural characteristics and acute outcomes with different pulsed field ablation systems for atrial fibrillationJournal of Interventional Cardiac Electrophysiology · 2026
- Contemporary pulsed field ablation systems for atrial fibrillation: a systematic review and network meta-analysisEuropean Heart Journal · 2026
- Clinical Outcomes of Pulsed Field Vs. Thermal Ablation for Paroxysmal Atrial Fibrillation: Systematic Review and Meta-Analysis of Randomized Evidence.Journal of arrhythmia · 2026
- Real-world one-year effectiveness of three pulsed field ablation systems for atrial fibrillationEuropean Heart Journal · 2026
- Pulsed Field Ablation Is Associated With Favorable Outcomes After Atrial Fibrillation Ablation: Insights From the Polish National Ablation Registry (POL-AR).Journal of cardiovascular electrophysiology · 2026
- Efficiency, Efficacy, and Energy-Specific Safety of Pulsed Field Versus Thermal Ablation in Paroxysmal Atrial Fibrillation: Insights From Contemporary Randomized Data (the E3-PFA Collaboration).Circulation. Arrhythmia and electrophysiology · 2026