Procedural characteristics and acute outcomes with different pulsed field ablation systems for atrial fibrillation
F. Ha, H C Han, AN Brown, N Nerlekar, Emily Kotschet
Monash Health
Key points
From the paper's conclusion- We performed a comparative observational study of consecutive patients undergoing PFA with three systems at a tertiary centre: Farawave without electroanatomic mapping (Boston Scientific, US), Faraview with integrated electroanatomic mapping (Boston Scientific, US) and Varipulse (Johnson and Johnson MedTech, US).
Abstract
BACKGROUND: Multiple different pulsed field ablation (PFA) systems have been developed for the treatment of atrial fibrillation (AF). An improved understanding of procedural workflow and outcomes are needed. METHODS: We performed a comparative observational study of consecutive patients undergoing PFA with three systems at a tertiary centre: Farawave without electroanatomic mapping (Boston Scientific, US), Faraview with integrated electroanatomic mapping (Boston Scientific, US) and Varipulse (Johnson and Johnson MedTech, US). All patients underwent pulmonary vein isolation (PVI) with additional lesions at operator discretion. RESULTS: A total of 150 patients undergoing PFA were included (50 with each system). Median age was 63-65 years (p = 0.28) and 28-38% female (p = 0.60). Persistent AF ranged from 40 to 62% (p = 0.09). More patients received posterior wall (PW) ablation with Faraview (50%) compared with Varipulse (26%) and Farawave (24%) (p = 0.01). Faraview was associated with more PV applications (52 versus 36; p < 0.001) although fewer PW applications (18 versus 24; p = 0.028) compared with Farawave. Procedure and left atrial catheter dwell times were higher with Varipulse compared with Farawave and Faraview (p < 0.001), but fluoroscopy time was lower (p < 0.001). Fluoroscopy use with Varipulse reduced in the second 25 cases compared with the first 25 cases (p = 0.01). There was no difference in rate of major or minor adverse events between groups. CONCLUSIONS: These real-world data on different PFA systems highlight varying procedural workflows depending on catheter design and the availability of additional information such as electroanatomic mapping and tissue contact. Further randomised studies are needed to compare safety and efficacy of different PFA systems for AF.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Pulsed Field Ablation Technologies for Atrial Fibrillation Ablation: a Systematic Review and Pairwise Meta-Analysis.Heart rhythm · 2026
- Real-world one-year effectiveness of three pulsed field ablation systems for atrial fibrillationEuropean Heart Journal · 2026
- Contemporary pulsed field ablation systems for atrial fibrillation: a systematic review and network meta-analysisEuropean Heart Journal · 2026
- Comparative Clinical and Procedural Outcomes Among Three Pulsed Field Ablation Systems for Atrial Fibrillation: A Prospective Real-World Study.Heart rhythm · 2026
- Does posterior wall ablation in conjunction with pulmonary vein isolation improve outcomes in patients with persistent atrial fibrillation undergoing pulsed field ablation?European Heart Journal · 2026
- Long-term efficacy of pulsed-field ablation devices in real-world atrial fibrillation patients: a direct comparison between the Farapulse and the Affera ablation systemsEuropean Heart Journal · 2026