Circulation. Arrhythmia and electrophysiology

Efficiency, Efficacy, and Energy-Specific Safety of Pulsed Field Versus Thermal Ablation in Paroxysmal Atrial Fibrillation: Insights From Contemporary Randomized Data (the E3-PFA Collaboration).

Shaojie Chen, Ramin Ebrahimi, Mu Qin, Jingquan Zhong, Kai Zhang, Huimin Chu, Christian Meyer, Andreas Rillig,

Rhythmology & Clinical Cardiac Electrophysiology, Clinic of Internal Medicine B (Cardiology, Angiology, Pneumology and Internal Intensive Care Medicine), German Centre for Cardiovascular Research (DZHK), University Medicine Greifswald (S.C., R.E.). · Department of Cardiology, Shanghai Chest Hospital (M.Q.).

Randomised · n=2,015

Key points

From the paper's conclusion
  • PFA provides greater procedural efficiency, improved peri-procedural safety, and a lower risk of atrial arrhythmia recurrence than pooled thermal ablation in patients with paroxysmal atrial fibrillation. The efficacy advantage was primarily driven by comparisons with cryoballoon ablation, whereas outcomes were comparable between PFA and contemporary RFA.

Abstract

BACKGROUND: Pulsed field ablation (PFA) is an increasingly adopted, minimally thermal modality for the ablation of atrial fibrillation, but its comparative performance versus contemporary thermal ablation strategies remains incompletely defined. We conducted an aggregate-data meta-analysis of contemporary randomized trials to compare procedural performance, safety, and clinical outcomes of PFA versus cryoballoon ablation and radiofrequency ablation in paroxysmal atrial fibrillation. METHODS: A systematic search identified 6 contemporary randomized controlled trials enrolling 2015 patients with paroxysmal atrial fibrillation. Study-level random-effects meta-analyses were performed to compare procedural performance, peri-procedural safety, and atrial arrhythmia recurrence, with predefined subgroup analyses according to thermal ablation modality. RESULTS: PFA was associated with significantly shorter procedure time, left atrial dwell time, and total ablation time than thermal ablation (all P<0.001), whereas fluoroscopy time and anesthetic strategy were comparable between groups. PFA was associated with a significantly lower risk of peri-procedural serious adverse events than thermal ablation (risk ratio, 0.58 [95% CI, 0.35-0.96]; P=0.036). Persistent phrenic nerve palsy and pulmonary vein stenosis occurred exclusively after thermal ablation. Overall, PFA was associated with a lower risk of atrial arrhythmia recurrence than pooled thermal ablation (risk ratio, 0.86 [95% CI, 0.75-0.99]; P=0.03). Subgroup analyses demonstrated a significant reduction in recurrence compared with cryoballoon ablation (risk ratio, 0.80 [95% CI, 0.65-0.97]; P=0.03), whereas outcomes were comparable between PFA and contemporary radiofrequency (risk ratio, 0.93 [95% CI, 0.77-1.13]; P=0.48). CONCLUSIONS: PFA provides greater procedural efficiency, improved peri-procedural safety, and a lower risk of atrial arrhythmia recurrence than pooled thermal ablation in patients with paroxysmal atrial fibrillation. The efficacy advantage was primarily driven by comparisons with cryoballoon ablation, whereas outcomes were comparable between PFA and contemporary RFA.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers