Procedural Success, Predictors of Failure, and Clinical Outcomes of Conduction System Pacing in Korea: The Korean Conduction System Pacing (K-CSP) Registry.
So-Ryoung Lee, Jongmin Hwang, Tae-Hoon Kim, Seung-Jung Park, Sung Soo Kim, Soonil Kwon, Woo-Hyun Lim, Jin Hee Choi,
Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea; Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea. · Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Republic of Korea.
Key points
From the paper's conclusion- In this large-scale Asian CSP registry, LBBAP was feasible and safe, performed predominantly with stylet-driven leads. Direct conduction system capture (LBBP+LFP) was associated with a lower adjusted risk of heart-failure hospitalization than LVSP, although this was based on few events; these findings are hypothesis-generating and warrant confirmation in randomized trials.
Abstract
BACKGROUND: Conduction system pacing (CSP), particularly left bundle branch area pacing (LBBAP), is a promising physiologic pacing strategy, but large-scale Asian data are lacking. OBJECTIVE: To evaluate the feasibility, predictors of failure, and clinical outcomes of CSP in a nationwide Korean multicenter registry. METHODS: This observational registry included 2,215 consecutive patients undergoing attempted CSP at 35 Korean centers between January 2021 and June 2025. Capture types were classified using EHRA criteria. RESULTS: Stylet-driven leads were used in 87.0%. CSP succeeded in 87.4% (1,932/2,211). Among 1,922 LBBAP patients, left bundle branch pacing (LBBP) was achieved in 35.1%, left fascicular pacing (LFP) in 31.3%, and left ventricular septal pacing (LVSP) in 17.2%. Independent predictors of CSP failure included prior open-heart surgery involving septal manipulation, right-sided approach, and male sex. Pacing parameters were stable over 17.0±10.8 months. CSP failure was associated with worse composite outcomes on unadjusted analysis, but these associations were attenuated and no longer significant after adjustment. Among LBBAP patients, LVSP was associated with a higher adjusted risk of heart-failure hospitalization (adjusted HR 3.04, 95% CI 1.05-8.73, p=0.039) than LBBP+LFP; however, this association was based on few events with wide confidence intervals and was not significant on unadjusted analysis. CONCLUSION: In this large-scale Asian CSP registry, LBBAP was feasible and safe, performed predominantly with stylet-driven leads. Direct conduction system capture (LBBP+LFP) was associated with a lower adjusted risk of heart-failure hospitalization than LVSP, although this was based on few events; these findings are hypothesis-generating and warrant confirmation in randomized trials.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transitioning into the new era of conduction system pacing (CSP): a district general hospital experience.The British journal of cardiology · 2026
- Cardiac Resynchronization Therapy Using a Conduction System Pacing Defibrillation Lead in Patients Meeting CRT-D Indications: Six-Month Clinical Outcomes Results From the ASCEND CSP Study.JACC. Clinical electrophysiology · 2026
- Conduction System Pacing for Resynchronization Therapy in Heart Failure: A Meta-Analysis of Randomized Controlled Trials.JACC. Asia · 2026
- Conduction system pacing as a rescue strategy for unsuccessful cardiac resynchronisation therapy implantation.Frontiers in physiology · 2026
- Learning by failing: conduction system pacing and decrease in left ventricular ejection fraction identified at implantEuropean Heart Journal · 2026
- Conduction System Pacing in Pediatric Patients: Outcomes From a Multicenter International Cohort.JACC. Clinical electrophysiology · 2026