Conduction system pacing as a rescue strategy for unsuccessful cardiac resynchronisation therapy implantation.
Kaung Myat Thu, Ibrahim Antoun, Kyi Zin Thant, Ahmed Abdelrazik, Mahmoud Eldesouky, Hamza Tarig Hamza, Sharon Man, Zakariyya Vali,
Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, United Kingdom.
Key points
From the paper's conclusion- CSP is a highly feasible and safe rescue strategy in patients with unsuccessful CRT implantation, achieving substantial electrical resynchronisation and meaningful recovery of left ventricular function. These findings support CSP as a compelling alternative in anatomically or technically challenging CRT cases where conventional resynchronisation delivery is not achievable.
Abstract
BACKGROUND: Failure to achieve effective cardiac resynchronisation therapy (CRT) remains a clinically significant challenge, often driven by anatomical constraints or suboptimal left ventricular lead performance. Conduction system pacing (CSP), incorporating His bundle pacing and left bundle branch area pacing, has emerged as a physiological alternative; however, data focussing specifically on its role as a rescue strategy following unsuccessful CRT implantation, rather than biological non-response, remain limited. OBJECTIVE: To evaluate the feasibility, safety, and short- to mid-term clinical and echocardiographic outcomes of CSP in patients with unsuccessful conventional CRT implantation. METHODS: In this single-centre retrospective study, consecutive patients undergoing attempted CSP after unsuccessful CRT between January 2020 and May 2025 were analysed. Unsuccessful CRT was defined as inability to deliver effective biventricular pacing due to anatomical or technical limitations, excluding patients with true non-response despite successful implantation. Procedural success, electrical resynchronisation, changes in left ventricular ejection fraction (LVEF), and clinical outcomes were assessed. RESULTS: Thirty-two patients (mean age 69 years, mean LVEF 27.8%) were included. CSP was successfully achieved in 91% of cases, predominantly using left bundle branch area pacing. Baseline QRS duration (165 ± 38 ms) significantly narrowed to 122 ± 19.8 ms following CSP. This was accompanied by marked improvement in LVEF (from 27.0 ± 8.6% to 47.7 ± 11.2%, p < 0.001). Procedural complications were infrequent, with one pneumothorax and no device-related infections. Over a mean follow-up of 641 ± 522 days, heart failure hospitalisation occurred in 7%, and three deaths were observed, non-attributable to device-related causes. CONCLUSION: CSP is a highly feasible and safe rescue strategy in patients with unsuccessful CRT implantation, achieving substantial electrical resynchronisation and meaningful recovery of left ventricular function. These findings support CSP as a compelling alternative in anatomically or technically challenging CRT cases where conventional resynchronisation delivery is not achievable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cardiac Resynchronization Therapy Using a Conduction System Pacing Defibrillation Lead in Patients Meeting CRT-D Indications: Six-Month Clinical Outcomes Results From the ASCEND CSP Study.JACC. Clinical electrophysiology · 2026
- Conduction System Pacing for Resynchronization Therapy in Heart Failure: A Meta-Analysis of Randomized Controlled Trials.JACC. Asia · 2026
- Conduction system pacing as a primary strategy for cardiac resynchronization therapy in reduced ejection fraction: An updated systematic review and meta-analysis of randomized controlled trialswe.Progress in cardiovascular diseases · 2026
- Direct His/LBB Pacing as an Alternative to Biventricular Pacing in Patients With HFrEF and a Typical LBBB: The His-Alternative II Study.JACC. Clinical electrophysiology · 2026
- Non-Invasive Methods for Identifying Electrical Responders to Conduction System Pacing Cardiac Resynchronization Therapy.Pacing and clinical electrophysiology : PACE · 2026
- Procedural Success, Predictors of Failure, and Clinical Outcomes of Conduction System Pacing in Korea: The Korean Conduction System Pacing (K-CSP) Registry.Heart rhythm · 2026