Evolution of Tined Leadless Pacemaker Implantation: Patient Selection, Implant Volume, Center Characteristics, and Safety Trends.
Jonathan P Piccini, Lucas Higuera, Yunshu Yang, George Crossley, Mikhael F El-Chami
Duke University Medical Center & Duke Clinical Research Institute, Durham, NC, USA,. Electronic address: jonathan.piccini@duke.edu. · Medtronic, Inc., Minneapolis, MN, USA.
Key points
From the paper's conclusion- In Medicare patients with tined leadless pacemakers, cardiac perforation rates declined over time and were lower in those implanted by more experienced implanters. Variation in outcomes was more closely associated with implanters than facilities.
Abstract
BACKGROUND: As leadless pacing approaches a decade in clinical practice, we sought to assess how device complications have changed over time, and how variations in patient, implanter volume, and facility characteristics are associated with these changes. OBJECTIVE: To examine rates of cardiac perforations after leadless pacemaker implantation over time, and the associations between patient, implanter volume, and facility characteristics with these outcomes, including the extent of variation attributable to implanters and facilities. METHODS: Medicare claims linked to a manufacturer's device registration data were used to identify patients implanted with a tined leadless pacemaker from 2017 to 2024. Patient selection across implanters and facilities was evaluated by examining differences in patient characteristics and their impact on patient-adjusted model estimates. Random-intercept models were fitted to estimate variation attributable to implanters and facilities. RESULTS: Among 46,698 implants, 19,446 (41.6%) were Micra AV; patients had a mean age of 80.4 years and a high Charlson Comorbidity Index (4.7±3.4). Cardiac perforation rates declined over time (adjusted Coefficient -0.13, 95% CI -0.19 - -0.06, p-value<0.01). Higher implanter volume was associated with fewer perforations (OR 0.93 per additional 10 implants, 95% CI 0.88-0.98; p-value<0.01). Differences in patient characteristics across providers and facilities were observed; however, adjustment for these differences did not materially alter the associations between implanters and facility and perforation rates. CONCLUSION: In Medicare patients with tined leadless pacemakers, cardiac perforation rates declined over time and were lower in those implanted by more experienced implanters. Variation in outcomes was more closely associated with implanters than facilities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adverse Event Profiles of Leadless Pacemaker Systems Reported to the FDA MAUDE Database (2021-2026).Journal of cardiovascular electrophysiology · 2026
- Leadless Pacemaker Use Following Transcatheter Aortic Valve Replacement: National Trends and Predictors, 2019-2023.Pacing and clinical electrophysiology : PACE · 2026
- A decade of leadless pacemaker implantation: technical performance, safety and device longevityEuropean Heart Journal · 2026
- Ten years follow-up data on a leadless pacing system – real life experience in comparison to data of the prospective trialEuropean Heart Journal · 2026
- A nationwide DRG-based analysis of leadless pacemaker implantation in germany: temporal trends, patient characteristics, and in-hospital outcomesEuropean Heart Journal · 2026
- Leadless Versus Transvenous Pacing: Propensity-Matched 12-Month Outcomes.Pacing and clinical electrophysiology : PACE · 2026