Safety and Outcomes of EUS-Guided Choledochoduodenostomy in Patients with a Common Bile Duct Diameter ≤15 mm.
Romik Srivastava, Clement Wu, Farimah Fayyaz, Romina Roshanshad, Olaya Brewer Gutierrez, Geraldine Keane, Yervant Ichkanian, Giuseppe Marzocca,
Johns Hopkins Hospital, Baltimore, Maryland, USA. · IRCCS San Raffaele Hospital, Milan, Italy.
Key points
From the paper's conclusion- EUS-CDS in bile ducts ≤15 mm achieved high technical success but carried an approximately 10% SMD risk. Two-step deployment was associated with fewer observed SMDs, whereas duodenal obstruction predicted later dysfunction. Larger-caliber LAMS was associated with fewer adverse events. These findings warrant prospective validation.
Abstract
BACKGROUND AND AIMS: EUS-guided choledochoduodenostomy (EUS-CDS) using lumen-apposing metal stents (LAMS) is an established biliary drainage strategy after failed ERCP, but deployment in extrahepatic bile ducts (≤15 mm) may increase technical risk. We evaluated outcomes and factors associated with stent misdeployment (SMD), dysfunction, and adverse events in this subgroup. METHODS: We performed a multicenter retrospective cohort study across 14 tertiary centers of adults undergoing EUS-CDS with cautery-enhanced LAMS in extrahepatic bile ducts ≤15 mm between 2014 and 2025. Prespecified multivariable logistic regression and Kaplan-Meier analyses were performed. RESULTS: Among 192 patients, 95.3% had malignant biliary obstruction; median bile duct diameter was 14.0 mm (IQR 12.0-14.9). Technical and clinical success were 91.7% and 90.1%, respectively. SMD occurred in 20 patients (10.4%), most commonly type I (80.0%). No lower duct-caliber threshold independently predicted technical failure or SMD. Two-step deployment had a lower unadjusted SMD rate than one-step deployment (3.3% vs 13.7%; P=0.039), but adjusted odds of SMD were lower without reaching statistical significance (aOR 0.25, 95% CI 0.05-1.16; P=0.076). Duodenal obstruction independently predicted stent dysfunction (aOR 2.26, 95% CI 1.02-4.99; P=0.044) and shorter dysfunction-free patency. LAMS ≥8 mm was independently associated with fewer adverse events (aOR 0.42, 95% CI 0.18-0.98; P=0.045). CONCLUSIONS: EUS-CDS in bile ducts ≤15 mm achieved high technical success but carried an approximately 10% SMD risk. Two-step deployment was associated with fewer observed SMDs, whereas duodenal obstruction predicted later dysfunction. Larger-caliber LAMS was associated with fewer adverse events. These findings warrant prospective validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Advanced endoscopic rescue after failed endoscopic ultrasound-guided choledochoduodenostomy.VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy · 2026
- EUS-Guided Choledochoduodenostomy with Lumen-Apposing Metal Stent versus ERCP with Self-Expandable Metal Stent as Primary Biliary Drainage for Malignant Distal Biliary Obstruction: A Systematic Review and Meta-Analysis of Randomized Controlled TrialsmedRxiv · 2026
- Electrocautery-Enhanced Lumen-Apposing Metal Stents Versus Modified Tubular Metal Stents for EUS-Guided Gallbladder Drainage: A Multicenter Study.Digestive endoscopy : official journal of the Japan Gastroenterological Endoscopy Society · 2026
- Transmural side holes in covered metal stents do not reduce bile duct occlusion or cholecystitis: a single center studymedRxiv · 2026
- EUS-Guided Choledochoduodenostomy Versus Hepaticogastrostomy in Case of Concomitant Gastric Outlet Obstruction Treated by EUS-Guided Gastroenterostomy: A Systematic Review and Meta-Analysis.United European gastroenterology journal · 2026
- Endoscopic suturing and flange modification of a biliary lumen-apposing metal stent for reduction of solid-food biliary reflux.VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy · 2026