A flexible electrochemical sensor array on disk for evaluating the quality of juice.
Wenqi Lin, Haixu Wang, Xiangjie Bo
Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Analysis and Testing Center, Department of Chemistry, Northeast Normal University, Changchun, Jilin Province 130024, PR China. · Liaoning Key Laboratory of Development and Utilization for Natural Products Active Molecules, School of Chemistry and Life Sciences, Anshan Normal University, Anshan, PR China.
Key points
From the paper's conclusion- We validate the usability of electrochemical sensor array on disk for monitoring of pH and AA in fresh juice under different sunlight exposure, different heating temperatures and different storage period.
Abstract
Evaluation of juice quality ensures the consumer safety, maintains nutritional quality and supports processing control and efficiency. Although existing evaluation methods for juice quality show high accuracy, these methods generally suffer from complicated operations and are not suitable for portable detection. Here, we present a flexible electrochemical sensor array on disk that offers on-site electrochemical monitoring of pH value and ascorbic acid (AA) in fresh juices. The sensor array shows Nernstian response to pH from 3.0 to 8.0 and sensitive linear response to AA in the concentration ranges of 10-200 and 200-2500 μM. We validate the usability of electrochemical sensor array on disk for monitoring of pH and AA in fresh juice under different sunlight exposure, different heating temperatures and different storage period.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- F-doped KMn4(PO4)3-based non-enzymatic electrochemical sensor for ascorbic acid and glucose: laboratory sensing and real-sample analysis.RSC advances · 2026
- Analytical quality by design for electrochemical nanostructured screen-printed sensor development: uric acid detection in saliva for diagnosis and monitoring of chronic diseases.Talanta · 2026
- An Autonomous pH Sensor for Real-Time High-Frequency Monitoring of Ocean Acidification in Estuarine and Coastal AreasAnalytical Chemistry · 2025
- An anthocyanin-curcumin colorimetric array with internal standard-guided feature switching for monitoring volatile alkaline nitrogen gases in meat freshness assessment.Analytical methods : advancing methods and applications · 2026
- Enhancing Food Safety with Microneedle-Based Biosensors: Real-Time Monitoring of Fish FreshnessACS Sensors · 2025
- Electrical and electrochemical pH sensing technologies: comparative mechanisms, performance, and applicationsJournal of Solid State Electrochemistry · 2026