RSC advances

F-doped KMn4(PO4)3-based non-enzymatic electrochemical sensor for ascorbic acid and glucose: laboratory sensing and real-sample analysis.

Hekmat Alham, Sana Ahsen, Taqdees Tariq, Javeria Ahmed, Maria Khalid, Farhan Younas, Talha Nisar, Veit Wagner,

Department of Chemistry, Quaid-i-Azam University Islamabad 45320 Pakistan aminbadshah@qau.edu.pk ahaider@qau.edu.pk. · H. E. J. Research Institute of Chemistry, International Center for Chemical and Biological Sciences, University of Karachi Karachi 75270 Pakistan.

Key points

From the paper's conclusion
  • In addition, the practical applicability of the sensor was confirmed through the quantification of ascorbic acid and glucose in real human blood serum samples, achieving maximum recoveries of up to 99% for both analytes.

Abstract

The accurate detection of ascorbic acid and glucose demands electrode materials with high conductivity and fast electron transfer. Fluorine doping is an effective strategy to modulate the electronic structure and improve the conductivity of phosphate-based materials. Owing to these benefits, fluorine-doped potassium manganese phosphate (F-doped KMn4(PO4)3) was synthesized by the co-precipitation method and characterized using powder X-ray diffraction (PXRD) analysis, energy-dispersive X-ray spectroscopy (EDX), scanning electron microscopy (SEM), and X-ray photoelectron spectroscopy (XPS). The synthesized material was coated onto a nickel foam electrode, and its electrochemical sensing performance towards ascorbic acid and glucose was evaluated by electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and chronoamperometry. The fabricated electrode exhibited excellent sensing metrics: low detection limits (0.07 µM for ascorbic acid and 0.10 µM for glucose), fast response (2 s for ascorbic acid and 3 s for glucose), high sensitivity (800 µA mM-1 cm-2 for ascorbic acid and 1070 µA mM-1 cm-2 for glucose), and broad linear ranges (10 µM-14 mM for ascorbic acid and 50 µM-14 mM for glucose), with excellent reproducibility (RSD: 1.70% for ascorbic acid and 2.90% for glucose), repeatability, operational stability, and selectivity. In addition, the practical applicability of the sensor was confirmed through the quantification of ascorbic acid and glucose in real human blood serum samples, achieving maximum recoveries of up to 99% for both analytes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers