Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons

Occupational radiation dose surveillance and radiation-protection compliance in podiatric surgery facilities: A nationwide cross-sectional study in Spain.

Manuel Cobo-Najar, Miguel Alcaraz, Daniel G Achel, Manuel Pardo-Ríos, José Antonio García-Gamuz, Amparo Olivares-Rueda

Department of Radiology and Physical Medicine, School of Medicine, Campus de Excelencia Internacional de Ámbito Regional (CEIR)-Campus Mare Nostrum (CMN), University of Murcia, Murcia 30100, Spain. Electronic address: mj.cobonajar@um.es. · Department of Radiology and Physical Medicine, School of Medicine, Campus de Excelencia Internacional de Ámbito Regional (CEIR)-Campus Mare Nostrum (CMN), University of Murcia, Murcia 30100, Spain.

Observational

Key points

From the paper's conclusion
  • Occupational doses appear low but are effectively unmonitored. Appropriate dose monitoring, consistent use of personal protective equipment, hand protection, and ALARA-compliant fluoroscopy practices are needed to ensure accurate surveillance and safer practice.

Abstract

BACKGROUND: Fluoroscopy is increasingly used in podiatric surgery, occupationally exposing podiatric surgeons. This study assessed radiation-protection knowledge, compliance, and estimated occupational doses in authorised podiatric radiology facilities. METHODS: A cross-sectional multicentre study included 55 facilities completing a radiation-protection questionnaire and 33 undergoing on-site inspection. Dose-equivalent rates were measured under routine conditions, and annual doses were estimated for the thorax, gonads, eye lens, and hands. RESULTS: Theoretical knowledge was adequate, but practical understanding of equipment was limited. No workers used personal dosimeters or protective equipment during exposures; thus, official dose reports reflected only background radiation. Lead aprons reduced thoracic and gonadal dose rates by about 99%. Estimated doses remained within regulatory limits, although hand exposure required particular attention. CONCLUSIONS: Occupational doses appear low but are effectively unmonitored. Appropriate dose monitoring, consistent use of personal protective equipment, hand protection, and ALARA-compliant fluoroscopy practices are needed to ensure accurate surveillance and safer practice.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers