Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)

Patient and occupational dosimetry in fluoroscopy-guided interventions in Spain: Progress made, gaps remaining.

Marta Barceló-Pagès, Luis Alejo Luque, Eva Corredoira Silva, José Manuel Ordiales Solís, María Pérez Fernández, Manuel Fco Rodríguez Castillo, Roberto M Sánchez Casanueva, Maria Amor Duch Guillen

Hospital de la Santa Creu i Sant Pau, Spain; Institut de Recerca Sant Pau (IR SANT PAU), Spain; Universitat Politècnica de Catalunya - BarcelonaTech (UPC), Spain. Electronic address: mbarcelop@santpau.cat. · Hospital General Universitario Gregorio Marañón, Spain.

Key points

From the paper's conclusion
  • Despite clear progress in recent years, significant variability persists in interventional dosimetry practices across Spanish centres. Wider implementation of DMS, stronger integration of DRLs into clinical workflows, and sustained investment in training and education are required to achieve harmonised and optimised radiation protection in line with European and international guidelines.

Abstract

PURPOSE: This study aimed to assess the current status of patient and occupational dosimetry practices in Spain and identify areas for improvement in relation to European and international recommendations. METHODS: Two nationwide surveys were conducted by a joint SEFM-SEPR working group, targeting medical physicists at centres performing fluoroscopy-guided interventional procedures. Key topics included DRLs, DMS, occupational radiation protection, certification, and training. Descriptive statistics were used to analyse the responses. RESULTS: A total of 38 responses were analysed for patient dosimetry and 32 for occupational radiation protection, with broad geographical representation. Most centres reported access to basic dosimetric data; however, 32 % lacked a dedicated DMS. Although 55 % of respondents reported using DRLs, routine application and physician involvement were limited. Patient dose calculations were performed in 58 % of centres but were mainly not recorded. In occupational radiation protection, the availability of personal protective equipment and eye lens dosimetry was high (97 %), while real-time dosimetry systems were implemented in 44 % of centres and not consistently quality-controlled. Variability was also observed in advanced certification, with only 22 % of centres meeting the requirements for second-level certification, and continuing education remained inconsistent. CONCLUSIONS: Despite clear progress in recent years, significant variability persists in interventional dosimetry practices across Spanish centres. Wider implementation of DMS, stronger integration of DRLs into clinical workflows, and sustained investment in training and education are required to achieve harmonised and optimised radiation protection in line with European and international guidelines.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers