Comparative Analysis of Radiation Protection Measures Used in Both Government and Private Radio-diagnostics Facilities in Port Harcourt Metropolis
Oluchi Ogba Okpoto, Michael Promise Ogolodom, M. A. Briggs Kamara, Egop Brownson Egop
Rivers State University
Key points
From the paper's conclusion- Independent sample t-test showed no statistically significant difference between government and private facilities in radiation protection practices (t = 0.03, p > 0.05), availability of equipment (t = 0.17, p > 0.05), and compliance with safety standards (t = 1.63, p > 0.05).
Abstract
Background: Radiographers, as healthcare workers bears the brunt of all the workplace hazards and as well faced with the most significant impact of occupational hazard due to the risk of poor and inadequate diagnostic machines, and poor knowledge regarding infection prevention measures. This study assessed and compared radiation protection measures in selected government and private radio-diagnostic facilities in Port Harcourt Metropolis. The study evaluated the availability of radiation protective equipment, compliance with radiation safety standards, and radiation dose levels in the selected facilities. Materials and methods: A cross-sectional research design was adopted using structured questionnaires and direct radiation measurements obtained with a survey meter. A total of 24 respondents participated in the study. Data were analyzed using descriptive statistics, independent sample t-test, and one-way ANOVA at a 0.05 level of significance. Results: The findings revealed that radiation protective equipment was generally available in both government and private facilities. Lead aprons were the most available protective devices, while thyroid shields were the least available, with only two recorded across all facilities. The mean availability score for radiation protective equipment was 1.60 ± 0.43 in government facilities and 1.63 ± 0.40 in private facilities. The mean radiation protection practice score was 3.62 ± 0.58 for government facilities and 3.60 ± 0.55 for private facilities. Independent sample t-test showed no statistically significant difference between government and private facilities in radiation protection practices (t = 0.03, p > 0.05), availability of equipment (t = 0.17, p > 0.05), and compliance with safety standards (t = 1.63, p > 0.05). However, one-way ANOVA revealed a significant difference among the selected facilities (F = 256.96, p < 0.05. Conclusion: The study concludes that radiation protection measures were generally implemented in both facility types. However, improvements in equipment availability, monitoring, maintenance, and staff training are required to further enhance radiation safety practices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Radiation Protection Practices in Classified Versus Non-Classified Areas of X-Ray Units in Jos Plateau StateNigerian Journal of Physics · 2026
- Evaluation of occupational radiation exposure and safety practices among orthopedic surgeons using C-arm fluoroscopy: a preliminary study at a hospital in Palestine.Radiation protection dosimetry · 2026
- Evaluation of radiation-protection drapes for reducing operator and patient radiation dose during overtable fluoroscopy: a phantom study.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- Diagnostic Radiographers' Application of the Radiation Protection Principles of Justification, Optimisation and Dose Limits in Mpumalanga Province, South Africa.Journal of medical radiation sciences · 2026
- Real-time occupational radiation dosimetry in anesthesiology personnel during fluoroscopy-guided interventions: a single-center descriptive and exploratory study.Frontiers in public health · 2026
- Occupational radiation protection in interventional radiology: A multicenter multimethod study of anesthesiology personnel.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026