Study on the Influence of Personnel Hand Activities in a Cleanroom on the Deposition Characteristics of Released Particulate Matter.
Hongfa Sun, Zhicheng Gao, Yuhui Xiao
College of Civil Engineering, Xiangtan University, Xiangtan, Hunan 411105, China. Electronic address: sunhf1212@xtu.edu.cn. · College of Civil Engineering, Xiangtan University, Xiangtan, Hunan 411105, China.
Key points
From the paper's conclusion- The results show that the total deposition of particles with diameters of 5 μm and 10 μm is significantly greater than that of particles with diameters ranging from 0.5 μm to 2 μm.
Abstract
Particulate matter released by human activities in cleanrooms poses not only a product contamination issue but also concerns regarding occupational exposure and indoor environmental quality. Particles in cleanroom air may carry microorganisms, chemical residues, or ultrafine fragments, which can be inhaled by workers or deposited on surfaces, potentially affecting human health and indoor environmental quality. Therefore, understanding the deposition behavior of particles released from hands is relevant to both contamination control and occupational exposure assessment. Based on this, this paper establishes a particle deposition model for hand movements of personnel in cleanrooms. The accuracy of the model is verified using existing experimental data. Through numerical simulations, the deposition characteristics of particles generated by hand operations on tabletops are investigated. A dimensionless relative deposition rate is proposed, and the final theoretical deposition model equation is solved. The study also analyzes particle deposition under various conditions, including the height of hand movements relative to the work surface, particle size, and different supply airflow velocities. The results show that the total deposition of particles with diameters of 5 μm and 10 μm is significantly greater than that of particles with diameters ranging from 0.5 μm to 2 μm. As the airflow velocity increases, the gap between the normalized deposition rates of particles of different sizes tends to decrease.For example, the ratio of deposition fractions between 10 μm and 5 μm particles decreased from 3.2 at 0.25 m/s to 1.25 at 0.45 m/s. The number of deposited particles tends to decrease with increasing height; specifically, the number of deposited particles at heights of 0.05 m, 0.10 m, and 0.15 m decreases significantly with increasing height, while the number of deposited particles at heights above 0.15 m maintains a gradual downward trend.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mathematical Model of Emergency Indoor Air Purification by Powder Aerosol.Toxics · 2026
- Airborne Microplastic Generation and Transport from 3D Printing Activities in a University SettingAerosol and Air Quality Research · 2026
- Airborne microplastics: a comprehensive analysis of indoor and outdoor pollution patterns.Reviews on environmental health · 2026
- Particulate-Matter Carcinogenic Risk in Thirteen European Indoor Micro-Environments: The Limits of Pre-Post Evaluation of Portable Air Cleaning (TwinAIR).Toxics · 2026
- Development of a Wearable Device for Precise Assessment of Particle Deposition in the Human Respiratory System.Environmental science & technology · 2026
- Evaluation of the Partector 2 Pro for measuring ultrafine particles emitted from 3D printing.Journal of occupational and environmental hygiene · 2026