Evaluation of the Partector 2 Pro for measuring ultrafine particles emitted from 3D printing.
Maryem Sabri, Loïc Wingert, Maximilien Debia, Isabelle Valois, Stéphane Hallé, Ludwig Vinches
Department of Environmental and Occupational Health, School of Public Health, Université de Montréal, Montreal, Canada. · Centre de recherche en santé publique, Montréal, Canada.
Key points
From the paper's conclusion- Overall, the Partector 2 Pro demonstrated reliable performance for real-time UFP number concentration monitoring during 3D printing.
Abstract
Additive manufacturing (3D printing) processes emit ultrafine particles (UFPs), raising concerns regarding occupational exposures and worker health. Portable diffusion-charging instruments may facilitate personal exposure monitoring; however, their performance under occupational 3D printing conditions remains insufficiently characterized. This study evaluated the Partector 2 Pro (Naneos GmbH, Windisch, Switzerland) against reference instruments during controlled printing of four commonly used thermoplastic filaments: polylactic acid (PLA), polyethylene terephthalate glycol (PETG), thermoplastic polyurethane (TPU/S-Flex), and nylon. Experiments were conducted in a wind tunnel to ensure stable emission conditions. Total particle number concentrations measured by the Partector 2 Pro were compared with those obtained from a scanning mobility particle sizer (SMPS) and a condensation particle counter (CPC), while particle size percentiles (D10 to D95) from the Partector 2 Pro were compared with those from the SMPS. For comparisons of concentrations, strong agreement was observed across all materials, with regression slopes ranging from 0.88 to 1.05 and Pearson's correlation coefficients higher than 0.96. Mean deviations ranged from -9.6% to +6.2%, remaining well within the manufacturer's stated ±30% accuracy specification. For comparisons of particle size metrics, the Partector 2 Pro systematically underestimated mobility diameters (slopes 0.82 to 0.90; r = 0.98 to 0.99). The magnitude of deviations was size-dependent, ranging from -27.0% to +7.5% for the smallest particles (D10), -28.3% to -7.3% for intermediate particles (D25 through D75), and -17.6% to -7.9% for the largest particles (D95). Overall, the Partector 2 Pro demonstrated reliable performance for real-time UFP number concentration monitoring during 3D printing. These results support its applicability for occupational exposure assessment and workplace surveillance in additive manufacturing settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and evaluation of four low-cost engineering controls for reducing particle emissions from 3D printing.Atmospheric Environment: X · 2026
- Tracing 3D printing emissions: Micro- and nanoplastic formation and the trade-off of mass-based mitigation.Journal of hazardous materials · 2026
- A 3D-printed hand-held visible spectrophotometric detector for point-of-care uric acid detection.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Influence of build-plate position and sequential printing on the colour fidelity of vat-photopolymerised microhybrid resinsProgress in Additive Manufacturing · 2026
- Airborne Microplastic Generation and Transport from 3D Printing Activities in a University SettingAerosol and Air Quality Research · 2026
- Filament deposition modeling quality assurance testing for the medical physicistJournal of Applied Clinical Medical Physics · 2026