Particulate-Matter Carcinogenic Risk in Thirteen European Indoor Micro-Environments: The Limits of Pre-Post Evaluation of Portable Air Cleaning (TwinAIR).
Ioanna P Chatziprodromidou, Rafail Fokas, Angeliki Chatziantoniou, Kalypso Angeliki Koukouvini, Stylianos Karatzas, Apostolos Vantarakis, TwinAIR Consortium
Department of Medicine, University of Patras, 26504 Patras, Greece. · Department of Civil Engineering, University of Patras, 26504 Patras, Greece.
Key points
From the paper's conclusion- We applied a probabilistic incremental lifetime cancer risk (ILCR) framework to size-resolved particulate matter in thirteen occupied micro-environments in five countries, monitored continuously at five-minute resolution within the TwinAIR pilot network, and then tested that evaluation design against the measurements it rests on.
Abstract
Indoor particulate matter is a Group 1 carcinogen with no identified exposure threshold, and the portable air cleaners now widely deployed in European schools, hospitals and offices are almost always evaluated by a change in mean concentration measured before and after installation in the same room. We applied a probabilistic incremental lifetime cancer risk (ILCR) framework to size-resolved particulate matter in thirteen occupied micro-environments in five countries, monitored continuously at five-minute resolution within the TwinAIR pilot network, and then tested that evaluation design against the measurements it rests on. Risk was uniformly low: every site-by-fraction estimate fell below the 10-6 de minimis threshold by between one and three orders of magnitude, and the conclusion survived recomputation from the measured concentration distributions (11.2 to 353 times below the threshold across forty-two estimates) and the substitution of paediatric exposure parameters. The evaluation design did not survive. In the two rooms that received air cleaners, measured PM2.5 rose by 7.8% and 21.0%, while a thermo-hygrometric regression explaining 1-6% of the variance-the concentration model underlying the probabilistic estimates-predicted reductions of 6.7% and 2.3%. Applying the same phase boundary to four sensors in three micro-environments that received no device produced changes from -74.3% to +37.2%, exceeding in magnitude and spanning in direction the contrast attributed to the intervention. The novelty of this work is therefore twofold: a harmonised probabilistic risk assessment of thirteen real occupied interiors on a single scale, and a demonstration, from the same network's data, that within-room pre-post designs without concurrent controls cannot identify an air-cleaning effect.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Contextual Factors That Impact the Performance of Portable Air Cleaners: A Critical ReviewEnvironmental Science & Technology · 2026
- Airborne microplastics: a comprehensive analysis of indoor and outdoor pollution patterns.Reviews on environmental health · 2026
- Size- and Time-Resolved Emission Rates of Particulate Matter Mass, Chemical Constituents, and Oxidative Potential from Indoor Sources.Environmental science & technology · 2026
- Evaluating air cleaner effectiveness in schools: a comprehensive review and protocol of a cluster-randomized controlled trial of physicochemical and microbial markers.Frontiers in public health · 2026
- Quantitative Microbial Risk Assessment of Airborne Viruses and Semi-Quantitative Bacterial Risk Scoring in Occupied European Indoor Environments: A Multi-Country StudyMicroorganisms · 2026
- Protective effect of reduced particulate matter exposure on pulmonary function and cognitive performance among school children: a cross-over trialEnvironmental Research · 2026