Fracture modelling of zirconia crowns in dental implant systems using XFEM, phase-field methods, and Weibull statistics.
Mojtaba Jalali, Rk Singh Raman, Mehrdad Abolghasemi, Mahmoud Mostafavi, Fatemeh Azhari
Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, Australia. Electronic address: mojtaba.jalali@monash.edu. · Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, Australia.
Key points
From the paper's conclusion- The proposed workflow combines deterministic crack modelling with probabilistic fracture assessment and provides a mechanics-based approach for evaluating fracture risk in implant-supported zirconia crowns.
Abstract
OBJECTIVES: This study aimed to develop a continuum-scale computational workflow for assessing fracture behaviour of zirconia crowns in dental implant systems under ISO 14801 loading conditions. METHODS: A three-dimensional finite element model of a Matrix multi-level implant system was developed. Global elastic analysis was first used to evaluate the maximum principal tensile stress distribution in the zirconia crown. The extended finite element method was then applied to assess damage initiation and crack-path development. A localized phase-field fracture sub-model was used to examine regularized damage evolution in the critical region. Weibull weakest-link analysis was applied to full-crown tensile stress fields to estimate fracture probability as a function of load. RESULTS: The global stress analysis identified the crown-indenter contact region as the critical tensile stress concentration. The extended finite element simulation predicted damage initiation beneath the indenter, followed by crack development toward the crown-implant interface. The phase-field sub-model showed progressive damage localization in the same critical region. Weibull analysis predicted a rapid increase in fracture probability within the load range corresponding to reported experimental fracture forces for similar implant-supported zirconia crowns. SIGNIFICANCE: The proposed workflow combines deterministic crack modelling with probabilistic fracture assessment and provides a mechanics-based approach for evaluating fracture risk in implant-supported zirconia crowns.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A fractographic and numerical assessment of dental zirconia implant fractures.Journal of the mechanical behavior of biomedical materials · 2026
- Biomechanical Performance of Zirconia–Calcium Silicate–Silver Hybrid Dental Crown Under Static and Transient Dynamic Loading: A Finite Element and TOPSIS ‐Based Multi‐Criteria EvaluationJournal of Biomedical Materials Research Part B Applied Biomaterials · 2026
- Thermo-mechanical loading of innovative "Mini-skirt" preparation design versus conventional full-coverage maxillary central incisor preparation design: an in vitro study.BMC oral health · 2026
- Asymmetric Metaphyseal Cones for AORI Type 2 Medial Defects in Tibial Plateau Fractures during Acute TKAJournal of Orthopaedic Research® · 2026
- Clinical Performance and Failure Mechanisms of Zirconia‐Based Toughened Ceramic CrownsInternational Journal of Applied Ceramic Technology · 2026
- Finite Element Analysis of Stress Distribution in Healthy and Restored Mandibular Molars with Zirconia and Lithium Disilicate Crowns Under Vertical and Oblique Loading.Journal of functional biomaterials · 2026